Audi TT (8N) Brake Electronics (MK60)

From Ross-Tech Wiki


Coding

ABS/EDS/ASR/ESP (Front-Wheel-Drive)

ABS/EDS/ASR/ESP (All-Wheel-Drive)

Basic Setting

Sensor for Steering Angle (G85)

Prerequisites:

  • Start the vehicle.
  • Turn the steering wheel one turn to the right and one turn to the left.
  • Drive in a short distance straight line on a level surface at a speed not higher than 20 km/h.
  • If the steering wheel is straight during the test drive then stop the vehicle with the wheels pointed straight.
  • Ensure that the steering wheel is not moved again.
  • Keep the engine running and do not switch off the ignition.
  • System voltage at least 12.0 V.

[Select]
[03 - Brake Electronics]
[Coding-II - 11]
Enter 40168, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 060
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
After a successful basic setting, field 2 should say "OK".
[Done, Go Back]
To make sure the basic setting was succesful, check the sensor again.
[Measuring Blocks - 08]
Group 004
[Go!]
Check field 1, the value has to be between -4.5 and +4.5 °.
[Done, Go Back]
[Close Controller, Go Back - 06]


Lateral Acceleration Sensor (G200)

Prerequisites:

  • System voltage at least 12.0 V.

[Select]
[03 - Brake Electronics]
[Measuring Blocks - 08]
Group 004
[Go!]
Check field 2, the value has to be between -1.5 and +1.5 m/s².
[Done, Go Back]
[Coding-II - 11]
Enter 40168, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 063
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
After a successful basic setting, field 2 should say "OK".
[Done, Go Back]
To make sure the basic setting was succesful, check the sensor again.
[Measuring Blocks - 08]
Group 004
[Go!]
Check field 2, the value has to be between -1.5 and +1.5 m/s².
[Done, Go Back]
[Close Controller, Go Back - 06]


Brake Pressure Sensor 1 (G201)

Prerequisites:

  • System voltage at least 12.0 V.

[Select]
[03 - Brake Electronics]
[Coding-II - 11]
Enter 40168, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 066
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
After a successful basic setting, field 2 should say "OK".
[Done, Go Back]
To make sure the basic setting was succesful, check the sensor again.
[Measuring Blocks - 08]
Group 005
[Go!]
Check field 1, the value has to be between -7.0 and +7.0 bar.
[Done, Go Back]
[Close Controller, Go Back - 06]


Longitudinal Acceleration Sensor (G251)

Prerequisites:

  • System voltage at least 12.0 V.
  • Measuring Value Block Group 006, Field 1 is between (-1.5) and (+1.5) m/s²

[Select]
[03 - Brake Electronics]
[Coding-II - 11]
Enter 40168, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 069
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
After a successful basic setting, field 2 should say "OK".
[Done, Go Back]
To make sure the basic setting was successful, check the sensor again.
[Measuring Blocks - 08]
Group 006
[Go!]
Re-Check field 1, the value has to be between -1.5 and +1.5 m/s².
[Done, Go Back]
[Close Controller, Go Back - 06]

Special Procedures

System Function Test

See System Function Test