Difference between revisions of "Readiness - APB Engine Code"
Line 57: | Line 57: | ||
''Evap purge test''<br> | ''Evap purge test''<br> | ||
− | Select group | + | Select group 070<br> |
'''[Go]'''<br> | '''[Go]'''<br> | ||
'''[Switch to basic settings]'''<br> | '''[Switch to basic settings]'''<br> | ||
− | Leave it in Basic Settings until the fourth field reads | + | Leave it in Basic Settings until the fourth field reads EVAP OK<br> |
'''[Switch to Meas. Blocks]'''<br> | '''[Switch to Meas. Blocks]'''<br> | ||
− | + | ''A/F control test''<br> | |
− | '' | + | |
− | + | Select group 107<br> | |
− | '''[ | + | '''[Go]'''<br> |
− | '''[ | + | '''[Switch to basic settings]'''<br> |
− | + | Leave it in Basic Settings until the fourth field reads Syst.OK<br> | |
− | + | '''[Switch to Meas. Blocks]'''<br> | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | '''[ | ||
− |
Revision as of 14:37, 5 October 2006
Manually Generating Readiness
- Ignition ON and Engine OFF
Reading and clearing fault codes
[Select]
[01 - Engine]
[Fault Codes - 02]
[Clear Codes -05]
[Done, Go Back]
Throttle Body Alignment
[Measuring Blocks - 08]
Select group 060
[Go]
[Switch to basic settings]
Once you do this you will see the top right display say ADP RUN. Leave it in Basic Settings until the fourth field reads ADP OK.
[Switch to Meas. Blocks]
Transmission kickdown (applies to Auto Trans vehicles only!)
Select group 063
[Go]
[Switch to basic settings]
Once you do this you will see the top right display say ADP RUN. Leave it in Basic Settings until the fourth field reads ADP OK.
[Switch to Meas. Blocks]
[Done, Go Back]
[Close Controller, Go Back]
- Ignition ON and Engine ON at idle
Fuel leakage test
[Select]
[01 - Engine]
[Measuring Blocks - 08]
Select group 071
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads Syst.OK
[Switch to Meas. Blocks]
Evap purge test
Select group 070
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads EVAP OK
[Switch to Meas. Blocks]
A/F control test
Select group 107
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads Syst.OK
[Switch to Meas. Blocks]