Difference between revisions of "Readiness - APB Engine Code"
Line 107: | Line 107: | ||
− | * <u>Ignition ON and Engine <b>ON between | + | * <u>Ignition ON and Engine <b>ON between 1520 and 2280 rpm</b></u><br> |
Line 113: | Line 113: | ||
''Pre-cat O2 sensors response time test''<br> | ''Pre-cat O2 sensors response time test''<br> | ||
− | Select group | + | Select group 034<br> |
'''[Go]'''<br> | '''[Go]'''<br> | ||
'''[Switch to basic settings]'''<br> | '''[Switch to basic settings]'''<br> | ||
− | Leave it in Basic Settings until | + | Leave it in Basic Settings until the fourth field reads B1-S1 OK<br> |
'''[Switch to Meas. Blocks]'''<br> | '''[Switch to Meas. Blocks]'''<br> | ||
− | Select group | + | Select group 035<br> |
'''[Go]'''<br> | '''[Go]'''<br> | ||
'''[Switch to basic settings]'''<br> | '''[Switch to basic settings]'''<br> | ||
− | Leave it in Basic Settings until | + | Leave it in Basic Settings until the fourth field reads B2-S1 OK<br> |
+ | '''[Switch to Meas. Blocks]'''<br> | ||
+ | |||
+ | |||
+ | |||
+ | * <u>Ignition ON and Engine <b>ON at idle</b></u><br> | ||
+ | |||
+ | |||
+ | |||
+ | ''O2 sensor control test''<br> | ||
+ | |||
+ | Select group 037<br> | ||
+ | '''[Go]'''<br> | ||
+ | '''[Switch to basic settings]'''<br> | ||
+ | Leave it in Basic Settings until the fourth field reads Syst. OK<br> | ||
+ | '''[Switch to Meas. Blocks]'''<br> | ||
+ | Select group 038<br> | ||
+ | '''[Go]'''<br> | ||
+ | '''[Switch to basic settings]'''<br> | ||
+ | Leave it in Basic Settings until the fourth field reads Syst. OK<br> | ||
'''[Switch to Meas. Blocks]'''<br> | '''[Switch to Meas. Blocks]'''<br> |
Revision as of 14:54, 5 October 2006
Manually Generating Readiness
- Ignition ON and Engine OFF
Reading and clearing fault codes
[Select]
[01 - Engine]
[Fault Codes - 02]
[Clear Codes -05]
[Done, Go Back]
Throttle Body Alignment
[Measuring Blocks - 08]
Select group 060
[Go]
[Switch to basic settings]
Once you do this you will see the top right display say ADP RUN. Leave it in Basic Settings until the fourth field reads ADP OK.
[Switch to Meas. Blocks]
Transmission kickdown (applies to Auto Trans vehicles only!)
Select group 063
[Go]
[Switch to basic settings]
Once you do this you will see the top right display say ADP RUN. Leave it in Basic Settings until the fourth field reads ADP OK.
[Switch to Meas. Blocks]
[Done, Go Back]
[Close Controller, Go Back]
- Ignition ON and Engine ON at idle
Fuel leakage test
[Select]
[01 - Engine]
[Measuring Blocks - 08]
Select group 071
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads Syst.OK
[Switch to Meas. Blocks]
Evap purge test
Select group 070
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads EVAP OK
[Switch to Meas. Blocks]
A/F control test
Select group 107
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads Syst.OK
[Switch to Meas. Blocks]
- Ignition ON and Engine ON between 1800 and 2200 rpm
O2 sensor heater test
Select group 041
[Go]
[Switch to basic settings]
Leave it in Basic Settings until there are kOhm readings in the first and third fields
[Switch to Meas. Blocks]
Select group 042
[Go]
[Switch to basic settings]
Leave it in Basic Settings until there are kOhm readings in the first and third fields
[Switch to Meas. Blocks]
- Ignition ON and Engine ON at idle
Post-cat O2 sensors readiness test
Select group 036
[Go]
[Switch to basic settings]
Leave it in Basic Settings until you see B1-S2 OK in the first field and B2-S2 OK in the third field
[Switch to Meas. Blocks]
- Ignition ON and Engine ON between 1520 and 2280 rpm
Pre-cat O2 sensors response time test
Select group 034
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads B1-S1 OK
[Switch to Meas. Blocks]
Select group 035
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads B2-S1 OK
[Switch to Meas. Blocks]
- Ignition ON and Engine ON at idle
O2 sensor control test
Select group 037
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads Syst. OK
[Switch to Meas. Blocks]
Select group 038
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads Syst. OK
[Switch to Meas. Blocks]