VW Touareg (7L) Heating/Air Conditioning: Difference between revisions

mNo edit summary
No edit summary
 
(One intermediate revision by the same user not shown)
Line 2: Line 2:
== Coding ==
== Coding ==


* '''000xx?0''': ''Glass Type''
* '''00xxx?0''': ''Glass Type''
** 2 = Standard Glass (Clear Glass)
** 2 = Standard Glass (Clear Glass)
** 3 = Thermal Protection Glass (Insulated/Acoustic Glass)
** 3 = Thermal Protection Glass (Insulated/Acoustic Glass)
* '''000x?x0''': ''Roof''
* '''00xx?x0''': ''Roof''
** 0 = Solar Roof not installed
** 0 = Solar Roof not installed & Anti-Whistle Measures inactive
** 1 = Anti-Whistle Measures active (only older Climate Control Units)
** 2 = Solar Roof installed
** 2 = Solar Roof installed
* '''000?xx0''': ''Refrigerant Loss Recognition''
** 3 = Solar Roof not installed & Anti-Whistle Measures active (4-Zone Climatronic)
** 4 = Solar Roof installed & Anti-Whistle Measures active (4-Zone Climatronic)
** 5 = Solar Roof not installed & Anti-Whistle Measures inactive & Without Acoustic Package
** 6 = Anti-Whistle Measures active  (only older Climate Control Units) & Without Acoustic Package
** 7 = Solar Roof installed & Without Acoustic Package
** 8 = Solar Roof not installed & Anti-Whistle Measures active (4-Zone Climatronic) & Without Acoustic Package
** 9 = Solar Roof installed & Anti-Whistle Measures active (4-Zone Climatronic) & Without Acoustic Package
* '''00x?xx0''': ''Refrigerant Loss Recognition''
** 0 = Refrigerant Temperature Sensor installed ''(Recognition activated)''
** 0 = Refrigerant Temperature Sensor installed ''(Recognition activated)''
** 1 = Refrigerant Temperature Sensor not installed ''(Recognition deactivated)''
** 1 = Refrigerant Temperature Sensor not installed ''(Recognition deactivated)''
 
** 2 = Refrigerant Temperature Sensor installed ''(Recognition activated / V6 FSI Engine)''
* '''00?xxx0''': ''Options''
** +1 = Climate Control Activation Delay (140 ms) active
** +2 = Anti-Fog Measures active (Hot Country/"Florida" Coding)


== Basic Setting ==
== Basic Setting ==
Line 17: Line 28:


'''<u>Prerequisites:</u>'''<br>
'''<u>Prerequisites:</u>'''<br>
*  
* Potentiometer / Flap replyed
* OR Climatronic Control Module (J255) replaced
* OR Climatronic Control Module (J255) recoded


'''[Select]'''<br>
'''[Select]'''<br>

Latest revision as of 14:12, 30 January 2008

Coding

  • 00xxx?0: Glass Type
    • 2 = Standard Glass (Clear Glass)
    • 3 = Thermal Protection Glass (Insulated/Acoustic Glass)
  • 00xx?x0: Roof
    • 0 = Solar Roof not installed & Anti-Whistle Measures inactive
    • 1 = Anti-Whistle Measures active (only older Climate Control Units)
    • 2 = Solar Roof installed
    • 3 = Solar Roof not installed & Anti-Whistle Measures active (4-Zone Climatronic)
    • 4 = Solar Roof installed & Anti-Whistle Measures active (4-Zone Climatronic)
    • 5 = Solar Roof not installed & Anti-Whistle Measures inactive & Without Acoustic Package
    • 6 = Anti-Whistle Measures active (only older Climate Control Units) & Without Acoustic Package
    • 7 = Solar Roof installed & Without Acoustic Package
    • 8 = Solar Roof not installed & Anti-Whistle Measures active (4-Zone Climatronic) & Without Acoustic Package
    • 9 = Solar Roof installed & Anti-Whistle Measures active (4-Zone Climatronic) & Without Acoustic Package
  • 00x?xx0: Refrigerant Loss Recognition
    • 0 = Refrigerant Temperature Sensor installed (Recognition activated)
    • 1 = Refrigerant Temperature Sensor not installed (Recognition deactivated)
    • 2 = Refrigerant Temperature Sensor installed (Recognition activated / V6 FSI Engine)
  • 00?xxx0: Options
    • +1 = Climate Control Activation Delay (140 ms) active
    • +2 = Anti-Fog Measures active (Hot Country/"Florida" Coding)

Basic Setting

Normal (Potentiometer & Flap Adaptation)

Prerequisites:

  • Potentiometer / Flap replyed
  • OR Climatronic Control Module (J255) replaced
  • OR Climatronic Control Module (J255) recoded

[Select]
[08 - Heating/Air Conditioning]
[Basic Settings - 04]
Group 001
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
The basic setting takes approximately 25 seconds.
[Done, Go Back]
[Close Controller, Go Back - 06]


Service Position

Notes:

  • Has to be performed before ANY Actuators/Motors are being removed.
  • While in Service Position the Display reads SF (German for "Servicefall").
  • Make sure to have the Ignition OFF while working on the Actuators/Motors.
  • Once all work has been done, switch ON the Ignition and perform the normal Basic Setting (Potentiometer & Flap Adaptation).

[Select]
[08 - Heating/Air Conditioning]
[Basic Settings - 04]
Group 002
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
The Display should read SFnow.
[Done, Go Back]
[Close Controller, Go Back - 06]