Difference between revisions of "16891/P0507/001287"
From Ross-Tech Wiki
RtWiKiSyS0p (talk | contribs) (New page: __FORCETOC__ == 16891/P0507/001287 - Idle Control System RPM: Higher than Expected. == ==== Possible Symptoms ==== * Malfunction Indicator Lamp (MIL) active ==== Possible Causes ==== *...) |
|||
Line 10: | Line 10: | ||
* Throttle Valve Control Module (J338) dirty/faulty | * Throttle Valve Control Module (J338) dirty/faulty | ||
* Wiring/Connector(s) from/to Throttle Valve Control Module (J338) | * Wiring/Connector(s) from/to Throttle Valve Control Module (J338) | ||
+ | * Vacuum Leak | ||
==== Possible Solutions ==== | ==== Possible Solutions ==== | ||
Line 15: | Line 16: | ||
* Check Throttle Valve Control Module (J338) | * Check Throttle Valve Control Module (J338) | ||
* Check Wiring/Connector(s) from/to Throttle Valve Control Module (J338) | * Check Wiring/Connector(s) from/to Throttle Valve Control Module (J338) | ||
+ | * Check Intake system for Leaks | ||
+ | |||
+ | ==== Special Notes ==== | ||
+ | |||
+ | * When found in the NAR 2.0T (BPY) check RVUTB: 01-09-03 or 2018919 for updated Crankcase Breather Valve | ||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Revision as of 17:46, 22 April 2010
16891/P0507/001287 - Idle Control System RPM: Higher than Expected.
Possible Symptoms
- Malfunction Indicator Lamp (MIL) active
Possible Causes
- Throttle Valve Control Module (J338) dirty/faulty
- Wiring/Connector(s) from/to Throttle Valve Control Module (J338)
- Vacuum Leak
Possible Solutions
- Check Throttle Valve Control Module (J338)
- Check Wiring/Connector(s) from/to Throttle Valve Control Module (J338)
- Check Intake system for Leaks
Special Notes
- When found in the NAR 2.0T (BPY) check RVUTB: 01-09-03 or 2018919 for updated Crankcase Breather Valve