01542: Difference between revisions

New page: __FORCETOC__ == 01542 - Yaw Rate Sensor (G202) == === 01542 - Yaw Rate Sensor (G202): Electrical Fault in Circuit === ==== Possible Symptoms ==== * Malfunction Indicator Light (MIL) act...
 
No edit summary
 
(2 intermediate revisions by the same user not shown)
Line 6: Line 6:
==== Possible Symptoms ====
==== Possible Symptoms ====


* Malfunction Indicator Light (MIL) active
* Malfunction Indicator Light (MIL) ON


==== Possible Causes ====
==== Possible Causes ====


* Wiring and/or Connector(s) from/to Yaw Rate Sensor (G202) faulty
* Yaw Rate Sensor (G202) faulty
* Yaw Rate Sensor (G202) faulty
* ESP-Sensor Unit (G419) faulty
* ESP-Sensor Unit (G419) faulty
Line 15: Line 16:
==== Possible Solutions ====
==== Possible Solutions ====


* Check Wiring and/or Connector(s) from/to Yaw Rate Sensor (G202)
* Check Yaw Rate Sensor (G202)
* Check Yaw Rate Sensor (G202)
** Check Measuring Value Block (MVB)
* Check ESP-Sensor Unit (G419)
* Check ESP-Sensor Unit (G419)


=== 01542 - Yaw Rate Sensor (G202): Implausible Signal ===
==== Possible Symptoms ====
* Malfunction Indicator Light (MIL) ON
==== Possible Causes ====
* Ground Wiring and/or Connector(s) from/to Yaw Rate Sensor (G202) faulty
* Installation Position of Yaw Rate Sensor (G202) incorrect
* Yaw Rate Sensor (G202) faulty
* ESP-Sensor Unit (G419) faulty
==== Possible Solutions ====
* Check Wiring and/or Connector(s) from/to Yaw Rate Sensor (G202)
* Check Installation Position of Yaw Rate Sensor (G202)
* Check Yaw Rate Sensor (G202)
** Check Measuring Value Block (MVB)
* Check ESP-Sensor Unit (G419)
=== 01542 - Yaw Rate Sensor (G202): No or Incorrect Basic Setting / Adaptation ===
==== Possible Causes ====
* Yaw Rate Sensor (G202) Basic Setting lost/not performed
==== Possible Solutions ====
* Perform Yaw Rate Sensor (G202) Basic Setting
** See Vehicle specific [[Diagnostic Procedures]] for Details
__FORCETOC__
[[Category:Fault Codes]]
[[Category:Fault Codes]]

Latest revision as of 02:24, 14 November 2010

01542 - Yaw Rate Sensor (G202)

01542 - Yaw Rate Sensor (G202): Electrical Fault in Circuit

Possible Symptoms

  • Malfunction Indicator Light (MIL) ON

Possible Causes

  • Wiring and/or Connector(s) from/to Yaw Rate Sensor (G202) faulty
  • Yaw Rate Sensor (G202) faulty
  • ESP-Sensor Unit (G419) faulty

Possible Solutions

  • Check Wiring and/or Connector(s) from/to Yaw Rate Sensor (G202)
  • Check Yaw Rate Sensor (G202)
    • Check Measuring Value Block (MVB)
  • Check ESP-Sensor Unit (G419)


01542 - Yaw Rate Sensor (G202): Implausible Signal

Possible Symptoms

  • Malfunction Indicator Light (MIL) ON

Possible Causes

  • Ground Wiring and/or Connector(s) from/to Yaw Rate Sensor (G202) faulty
  • Installation Position of Yaw Rate Sensor (G202) incorrect
  • Yaw Rate Sensor (G202) faulty
  • ESP-Sensor Unit (G419) faulty

Possible Solutions

  • Check Wiring and/or Connector(s) from/to Yaw Rate Sensor (G202)
  • Check Installation Position of Yaw Rate Sensor (G202)
  • Check Yaw Rate Sensor (G202)
    • Check Measuring Value Block (MVB)
  • Check ESP-Sensor Unit (G419)


01542 - Yaw Rate Sensor (G202): No or Incorrect Basic Setting / Adaptation

Possible Causes

  • Yaw Rate Sensor (G202) Basic Setting lost/not performed

Possible Solutions