17819/P1411/005137: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
RtWiKiSyS0p (talk | contribs) No edit summary |
No edit summary |
||
| (One intermediate revision by the same user not shown) | |||
| Line 9: | Line 9: | ||
* Fuse for Secondary Air Injection Pump blown | * Fuse for Secondary Air Injection Pump blown | ||
* Vacuum Hose(s) leaky | * Vacuum Hose(s) leaky or collapsed | ||
* Piping between Secondary Air Injection Pump and Secondary Air Injection Valve leaking | * Piping between Secondary Air Injection Pump and Combi (Secondary Air Injection) Valve leaking | ||
* Secondary Air Injection Solenoid(s) faulty | |||
* Combi Valve(s) faulty | |||
==== Possible Solutions ==== | ==== Possible Solutions ==== | ||
| Line 16: | Line 18: | ||
* Check Fuse for Secondary Air Injection Pump | * Check Fuse for Secondary Air Injection Pump | ||
* Check Vacuum Hose(s) | * Check Vacuum Hose(s) | ||
* Check Piping between Secondary Air Injection Pump and Secondary Air Injection Valve | * Check Piping between Secondary Air Injection Pump and Combi (Secondary Air Injection) Valve | ||
* Check Secondary Air Injection Solenoid(s) | |||
* Check Combi Valve(s) | |||
[[Category:Fault Codes]] | [[Category:Fault Codes]] | ||
Latest revision as of 02:53, 4 March 2011
17819/P1411/005137 - Secondary Air Injection System; Bank 2: Insufficient Flow
Possible Symptoms
- Malfunction Indicator Light (MIL) active
Possible Causes
- Fuse for Secondary Air Injection Pump blown
- Vacuum Hose(s) leaky or collapsed
- Piping between Secondary Air Injection Pump and Combi (Secondary Air Injection) Valve leaking
- Secondary Air Injection Solenoid(s) faulty
- Combi Valve(s) faulty
Possible Solutions
- Check Fuse for Secondary Air Injection Pump
- Check Vacuum Hose(s)
- Check Piping between Secondary Air Injection Pump and Combi (Secondary Air Injection) Valve
- Check Secondary Air Injection Solenoid(s)
- Check Combi Valve(s)