Difference between revisions of "Audi A6 (4G/4H) Headlight Regulation Basic"
(Created page with "__FORCETOC__ This page applies to Audi A6/A7/A8 (4G/4H) Chassis vehicles with '''Headlight Regulation Basic''' LED headlights. This can be identified by evaluating the data ...") |
|||
(One intermediate revision by the same user not shown) | |||
Line 1: | Line 1: | ||
__FORCETOC__ | __FORCETOC__ | ||
− | This page applies to Audi A6/A7/A8 (4G/4H) Chassis vehicles with '''Headlight Regulation Basic''' LED headlights. This can be identified by evaluating the data in the Auto-Scan: | + | This page applies to Audi A4 (8K/FL) and A6/A7/A8 (4G/4H) Chassis vehicles with '''Headlight Regulation Basic''' LED headlights. This can be identified by evaluating the data in the Auto-Scan: |
− | Address 55: Xenon Range (J431) Labels: | + | Address 55: Xenon Range (J431) Labels: 8X0-907-357.clb |
Part No SW: 4H0 907 357 A HW: 4H0 907 357 A | Part No SW: 4H0 907 357 A HW: 4H0 907 357 A | ||
Component: ....LWR12.... H02 0013 | Component: ....LWR12.... H02 0013 |
Latest revision as of 10:15, 30 June 2020
This page applies to Audi A4 (8K/FL) and A6/A7/A8 (4G/4H) Chassis vehicles with Headlight Regulation Basic LED headlights. This can be identified by evaluating the data in the Auto-Scan:
Address 55: Xenon Range (J431) Labels: 8X0-907-357.clb Part No SW: 4H0 907 357 A HW: 4H0 907 357 A Component: ....LWR12.... H02 0013 ASAM Dataset: EV_HeadlRegulBasic 005001 ROD: EV_HeadlRegulBasic.rod
Coding
Adaptation
Security Access
- Will appear in a pop-up balloon when connected to this controller.
Basic Setting
Headlight Adjustment
Prerequisites:
- Vehicle must be parked on level ground and settled on its suspension
[Select]
[55 - Xenon Range]
[Basic Settings - 04]
Select Basic headlamp setting from the drop-down menu.
[Go!] to activate the Basic Setting.
- The meas. block field will show Running.
- Adjust the headlights using their manual adjusting screws as referenced against a suitable aiming target.
[Stop] after any needed mechanical adjustments are completed.
Select Acknowledge basic setting
[Go!] to activate the Basic Setting.
The adjustment should now be learned.
[Stop]
[Done, Go Back]
Don't forget to check/clear fault codes afterwards.
[Close Controller, Go Back - 06]