          B10A9 - Control Circuit for A/C Compressor
          
- 
      
      1.1.1
      B10A911 - Control Circuit A/C Compressor: Short to Ground
      
- 1.1.1.2 Possible Symptoms
 
- 1.1.2.2 Possible Causes
 
- 1.1.3.2 Possible Solutions
 
 
- 
      
      1.2.1
      B10A915 - Control Circuit A/C Compressor: Open or Short to Plus
      
- 1.2.1.6 Possible Symptoms
 
- 1.2.2.6 Possible Causes
 
- 1.2.3.6 Possible Solutions
 
- 1.2.4.6 Special Notes
 
 
 - 
      
      1.1.1
      B10A911 - Control Circuit A/C Compressor: Short to Ground
      
 
No edit summary  | 
				|||
| Line 36: | Line 36: | ||
* Fuse(s) faulty  | * Fuse(s) faulty  | ||
* Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280) faulty  | * Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280) faulty  | ||
** The wrong 2-wire electrical connector is plugged into the Regulating Valve (N280)  | |||
* Compressor Regulating Valve (N280) faulty  | * Compressor Regulating Valve (N280) faulty  | ||
* Heating/Climate Control Module (J301) faulty  | * Heating/Climate Control Module (J301) faulty  | ||
| Line 43: | Line 44: | ||
* Check Fuse(s)  | * Check Fuse(s)  | ||
* Check Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280)  | * Check Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280)  | ||
** Verify the color of the wires matches the ones shown in the wiring diagram for N280 as per [https://forums.ross-tech.com/index.php?threads/633/ this thread]  | |||
* Check/Replace Compressor Regulating Valve (N280)  | * Check/Replace Compressor Regulating Valve (N280)  | ||
** Check Measuring Value Blocks (MVB)  | ** Check Measuring Value Blocks (MVB)  | ||
Latest revision as of 21:54, 5 May 2021
B10A9 - Control Circuit for A/C Compressor
B10A911 - Control Circuit A/C Compressor: Short to Ground
Possible Symptoms
- Climate Control not working (Not cooling)
 
Possible Causes
- Fuse(s) faulty
 - Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280) faulty
 - Compressor Regulating Valve (N280) faulty
 - Heating/Climate Control Module (J301) faulty
 
Possible Solutions
- Check Fuse(s)
 - Check Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280)
 - Check/Replace Compressor Regulating Valve (N280)
- Check Measuring Value Blocks (MVB)
 - Perform Output Test
 
 - Check/Replace Heating/Climate Control Module (J301)
 
B10A915 - Control Circuit A/C Compressor: Open or Short to Plus
Possible Symptoms
- Climate Control not working (Not cooling)
 
Possible Causes
- Fuse(s) faulty
 - Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280) faulty
- The wrong 2-wire electrical connector is plugged into the Regulating Valve (N280)
 
 - Compressor Regulating Valve (N280) faulty
 - Heating/Climate Control Module (J301) faulty
 
Possible Solutions
- Check Fuse(s)
 - Check Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280)
- Verify the color of the wires matches the ones shown in the wiring diagram for N280 as per this thread
 
 - Check/Replace Compressor Regulating Valve (N280)
- Check Measuring Value Blocks (MVB)
 - Perform Output Test
 
 - Check/Replace Heating/Climate Control Module (J301)
 
Special Notes
- The Refrigerant Compressor may need to be replaced if the Compressor Regulating Valve (N280) is not available separately.
 
- When found in the (4H) Audi A8 chassis 08-Auto HVAC control module, check the N280 AC compressor wiring to/from J519 per the factory level Wiring Diagram.