Difference between revisions of "Audi TT (8J)Automatic Roof"
From Ross-Tech Wiki
(Created page with "__FORCETOC__ == Coding == Not Applicable == Adaptation == When performing repairs/replacement of the Flap Motors it will be necessary to perform the Adaption of the Flap Mo...") |
|||
(4 intermediate revisions by 2 users not shown) | |||
Line 6: | Line 6: | ||
== Adaptation == | == Adaptation == | ||
− | + | After repairs/replacement of the Flap Motors it will be necessary to perform the | |
− | Adaption of the Flap Motors. | + | Adaption of the Flap Motors. Useful references include:<br> |
− | + | * NAR (North American Region) TSB 61-09-02 or 2018777 | |
− | The faults associated with the bulletins include: [[02000]], [[03246]], and [[03247]]. | + | * NAR (North American Region) TPI 2015779: |
+ | ** https://static.nhtsa.gov/odi/tsbs/2013/MC-10121348-9999.pdf NHTSA | ||
+ | * The faults associated with the bulletins include: [[02000]], [[03246]], and [[03247]]. <br> | ||
− | + | ||
+ | After diagnosis and repairs perform the following Output Test: | ||
'''[Select]'''<br> | '''[Select]'''<br> | ||
'''[26 - Auto Roof]'''<br> | '''[26 - Auto Roof]'''<br> | ||
'''[Output Tests - 03]'''<br> | '''[Output Tests - 03]'''<br> | ||
− | '''[Select]''' Selective Output Tests | + | '''[Select]''' Selective Output Tests<br> |
− | + | '''[Choose]'''''Convertible Top Flap Initialisation'' <br> | |
− | + | '''[Start]'''<br> | |
− | '''[ | + | '''Operate''' the Convertible Top throughout a complete Open/Close sequence BEFORE exiting the Output Test function.<br> |
− | |||
− | |||
− | '''[Start]''' | ||
− | |||
− | |||
− | |||
− | '''Operate''' the Convertible Top | ||
− | |||
'''[Done, Go Back]'''<br> | '''[Done, Go Back]'''<br> | ||
'''[Close Controller, Go Back - 06]'''<br><br> | '''[Close Controller, Go Back - 06]'''<br><br> | ||
− | |||
− | |||
− | + | This thread contains 8J chassis [26-Auto Roof] data: | |
− | * | + | * https://www.ttforum.co.uk/threads/faq-mk2-roadster-convertible-measurement-blocks-fault-codes-adaptation.2019023/ |
− | * | + | ** Members of our Ross-Tech forum can post in this thread http://forums.ross-tech.com/showthread.php?14543-VCDS-Module-for-Audi-TT-Mk2-(8J)-Roadster-26-Auto-Roof-Group-Codes |
Latest revision as of 11:25, 18 October 2024
Coding
Not Applicable
Adaptation
After repairs/replacement of the Flap Motors it will be necessary to perform the
Adaption of the Flap Motors. Useful references include:
- NAR (North American Region) TSB 61-09-02 or 2018777
- NAR (North American Region) TPI 2015779:
- The faults associated with the bulletins include: 02000, 03246, and 03247.
After diagnosis and repairs perform the following Output Test:
[Select]
[26 - Auto Roof]
[Output Tests - 03]
[Select] Selective Output Tests
[Choose]Convertible Top Flap Initialisation
[Start]
Operate the Convertible Top throughout a complete Open/Close sequence BEFORE exiting the Output Test function.
[Done, Go Back]
[Close Controller, Go Back - 06]
This thread contains 8J chassis [26-Auto Roof] data: