01049: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
-
1.
01049 - Supply Voltage Term 50
-
1.1.1
01049 - Supply Voltage Term 50: Short to Plus
- 1.1.1.2 Possible Causes
- 1.1.2.2 Possible Solutions
- 1.1.3.2 Special Notes
-
1.1.1
01049 - Supply Voltage Term 50: Short to Plus
RtWiKiSyS0p (talk | contribs) No edit summary |
No edit summary |
||
| (One intermediate revision by one other user not shown) | |||
| Line 1: | Line 1: | ||
__FORCETOC__ | __FORCETOC__ | ||
== 01049 - Supply Voltage Term 50 == | == 01049 - Supply Voltage Term 50 == | ||
=== 01049 - Supply Voltage Term 50: Short to Plus === | |||
==== Possible Causes ==== | |||
* Fuse(s) faulty | |||
* Wiring and/or Connector(s) from/to Starter Relay (J53) faulty | |||
* Starter Relay (J53) faulty | |||
==== Possible Solutions ==== | |||
* Check Fuse(s) | |||
* Check Wiring and/or Connector(s) from/to Starter Relay (J53) | |||
* Check/Replace Starter Relay (J53) | |||
==== Special Notes ==== | |||
* When found in [[Audi A6/S6/RS6/allroad (4F)|Audi A6 (4F)]]: Access/Start Authorization, check Measuring Value Blocks. | |||
=== 01049 - Supply Voltage Term 50: Electrical Fault in Circuit === | === 01049 - Supply Voltage Term 50: Electrical Fault in Circuit === | ||
Latest revision as of 21:50, 5 February 2020
01049 - Supply Voltage Term 50
01049 - Supply Voltage Term 50: Short to Plus
Possible Causes
- Fuse(s) faulty
- Wiring and/or Connector(s) from/to Starter Relay (J53) faulty
- Starter Relay (J53) faulty
Possible Solutions
- Check Fuse(s)
- Check Wiring and/or Connector(s) from/to Starter Relay (J53)
- Check/Replace Starter Relay (J53)
Special Notes
- When found in Audi A6 (4F): Access/Start Authorization, check Measuring Value Blocks.
01049 - Supply Voltage Term 50: Electrical Fault in Circuit
Possible Solutions
- Check Ignition Switch (D) Terminal 50