02456: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
-
1.
02456 - Line Filling
-
1.1.1
02456 - Line Filling: No or Incorrect Basic Setting / Adaptation
- 1.1.1.2 Possible Symptoms
- 1.1.2.2 Possible Causes
- 1.1.3.2 Possible Solutions
- 1.1.4.2 Special Notes
-
1.1.1
02456 - Line Filling: No or Incorrect Basic Setting / Adaptation
RtWiKiSyS0p (talk | contribs) New page: __FORCETOC__ == 02456 - Line Filling == === 02456 - Line Filling: No or Incorrect Basic Setting / Adaptation === ==== Possible Symptoms ==== * Fault Code can not be erased ==== Possibl... |
RtWiKiSyS0p (talk | contribs) No edit summary |
||
| Line 19: | Line 19: | ||
==== Special Notes ==== | ==== Special Notes ==== | ||
* When found in [[VW Touran (1T)]]: [[VW Touran (1T) Auxiliary Heating|Auxiliary Heating]] ''(or similar)'', | * When found in [[VW Touran (1T)]]: [[VW Touran (1T) Auxiliary Heating|Auxiliary Heating]] ''(or similar)'', perform Line Filling. | ||
** Set Adaptation Channel 030 to a New Value of 30. | |||
** Set Adaptation Channel 043 to a New Value of 0. | |||
** Perform Basic Setting in Measuring Value Block (MVB) 066. | |||
[[Category:Fault Codes]] | [[Category:Fault Codes]] | ||
Latest revision as of 14:43, 30 December 2008
02456 - Line Filling
02456 - Line Filling: No or Incorrect Basic Setting / Adaptation
Possible Symptoms
- Fault Code can not be erased
Possible Causes
- Line Filling not performed
- New Auxiliary Heater installed
Possible Solutions
- Perform Line Filling
Special Notes
- When found in VW Touran (1T): Auxiliary Heating (or similar), perform Line Filling.
- Set Adaptation Channel 030 to a New Value of 30.
- Set Adaptation Channel 043 to a New Value of 0.
- Perform Basic Setting in Measuring Value Block (MVB) 066.