Difference between revisions of "00668"

From Ross-Tech Wiki
(New page: == 00668 - Supply Voltage Terminal 30 == === 00668 - Supply Voltage Terminal 30: Signal Outside Specifications === ==== Possible Causes ==== * Fuse(s) faulty * Wiring/Connectors from/to...)
 
 
(One intermediate revision by the same user not shown)
Line 2: Line 2:
  
 
=== 00668 - Supply Voltage Terminal 30: Signal Outside Specifications ===
 
=== 00668 - Supply Voltage Terminal 30: Signal Outside Specifications ===
 +
=== 00668 - Supply Voltage Terminal 30: Implausible Signal ===
  
 
==== Possible Causes ====
 
==== Possible Causes ====
Line 20: Line 21:
 
* When found in multiple control modules at the same time, it's most likely a common source (e.g. ground spot, battery, generator).
 
* When found in multiple control modules at the same time, it's most likely a common source (e.g. ground spot, battery, generator).
 
* Intermittent codes are often stored during low outside temperature when the battery capacity goes down and may be ignored.
 
* Intermittent codes are often stored during low outside temperature when the battery capacity goes down and may be ignored.
 +
 +
[[Category:Fault Codes]]

Latest revision as of 07:28, 14 June 2008

00668 - Supply Voltage Terminal 30

00668 - Supply Voltage Terminal 30: Signal Outside Specifications

00668 - Supply Voltage Terminal 30: Implausible Signal

Possible Causes

  • Fuse(s) faulty
  • Wiring/Connectors from/to Control Module faulty
  • Power Supply (Battery/Generator) faulty

Possible Solutions

  • Check Fuse(s)
  • Check/Repair Wiring/Connectors from/to Control Module
  • Check Power Supply (Battery/Generator)

Special Notes

  • When found in an individual control module, it's most likely a local source (e.g. wiring/connectors).
  • When found in multiple control modules at the same time, it's most likely a common source (e.g. ground spot, battery, generator).
  • Intermittent codes are often stored during low outside temperature when the battery capacity goes down and may be ignored.