Difference between revisions of "01809"
From Ross-Tech Wiki
(New page: __FORCETOC__ == 01809 - Actuating Motor for Temperature Flap; Left (V158) == === 01800 - Actuating Motor for Temperature Flap; Blocked or No Voltage === ==== Possible Symptoms ==== * HV...) |
|||
Line 2: | Line 2: | ||
== 01809 - Actuating Motor for Temperature Flap; Left (V158) == | == 01809 - Actuating Motor for Temperature Flap; Left (V158) == | ||
− | === | + | === 01809 - Actuating Motor for Temperature Flap; Blocked or No Voltage === |
==== Possible Symptoms ==== | ==== Possible Symptoms ==== |
Latest revision as of 11:36, 25 July 2014
01809 - Actuating Motor for Temperature Flap; Left (V158)
01809 - Actuating Motor for Temperature Flap; Blocked or No Voltage
Possible Symptoms
- HVAC temperature inconsistent.
Possible Causes
- Left Temperature Flap (V158) faulty
- Wiring/Connectors between Left Temperature Flap (V158) and A/C Control Head (E87) faulty
- Temperature flap stuck or obstructed (unable to move freely)
Possible Solutions
- Check Wiring/Connectors between Left Temperature Flap (V158) and A/C Control Head (E87) faulty
- Run Output Tests to make sure Left Temperature Flap (V158) can operate freely.