B10A9: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
-
1.
B10A9 - Control Circuit for A/C Compressor
-
1.1.1
B10A911 - Control Circuit A/C Compressor: Short to Ground
- 1.1.1.2 Possible Symptoms
- 1.1.2.2 Possible Causes
- 1.1.3.2 Possible Solutions
-
1.2.1
B10A915 - Control Circuit A/C Compressor: Open or Short to Plus
- 1.2.1.6 Possible Symptoms
- 1.2.2.6 Possible Causes
- 1.2.3.6 Possible Solutions
- 1.2.4.6 Special Notes
-
1.1.1
B10A911 - Control Circuit A/C Compressor: Short to Ground
Created page with "__FORCETOC__ == B10A9 - Control Circuit for A/C Compressor == ==== Special Notes ==== * When found in the (4H) Audi A8 chassis 08-Auto HVAC control module, check the N280 AC..." |
|||
(One intermediate revision by one other user not shown) | |||
Line 1: | Line 1: | ||
__FORCETOC__ | __FORCETOC__ | ||
== B10A9 - Control Circuit for A/C Compressor == | == B10A9 - Control Circuit for A/C Compressor == | ||
=== B10A911 - Control Circuit A/C Compressor: Short to Ground === | |||
==== Possible Symptoms ==== | |||
* Climate Control not working (Not cooling) | |||
==== Possible Causes ==== | |||
* Fuse(s) faulty | |||
* Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280) faulty | |||
* Compressor Regulating Valve (N280) faulty | |||
* Heating/Climate Control Module (J301) faulty | |||
==== Possible Solutions ==== | |||
* Check Fuse(s) | |||
* Check Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280) | |||
* Check/Replace Compressor Regulating Valve (N280) | |||
** Check Measuring Value Blocks (MVB) | |||
** Perform Output Test | |||
* Check/Replace Heating/Climate Control Module (J301) | |||
=== B10A915 - Control Circuit A/C Compressor: Open or Short to Plus === | |||
==== Possible Symptoms ==== | |||
* Climate Control not working (Not cooling) | |||
==== Possible Causes ==== | |||
* Fuse(s) faulty | |||
* Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280) faulty | |||
** The wrong 2-wire electrical connector is plugged into the Regulating Valve (N280) | |||
* Compressor Regulating Valve (N280) faulty | |||
* Heating/Climate Control Module (J301) faulty | |||
==== Possible Solutions ==== | |||
* Check Fuse(s) | |||
* Check Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280) | |||
** Verify the color of the wires matches the ones shown in the wiring diagram for N280 as per [https://forums.ross-tech.com/index.php?threads/633/ this thread] | |||
* Check/Replace Compressor Regulating Valve (N280) | |||
** Check Measuring Value Blocks (MVB) | |||
** Perform Output Test | |||
* Check/Replace Heating/Climate Control Module (J301) | |||
==== Special Notes ==== | ==== Special Notes ==== | ||
* The Refrigerant Compressor may need to be replaced if the Compressor Regulating Valve (N280) is not available separately. | |||
* When found in the (4H) Audi A8 chassis 08-Auto HVAC control module, check the N280 AC compressor wiring to/from J519 per the factory level [[Official Factory Repair Information |Wiring Diagram]]. | * When found in the (4H) Audi A8 chassis 08-Auto HVAC control module, check the N280 AC compressor wiring to/from J519 per the factory level [[Official Factory Repair Information |Wiring Diagram]]. |
Latest revision as of 21:54, 5 May 2021
B10A9 - Control Circuit for A/C Compressor
B10A911 - Control Circuit A/C Compressor: Short to Ground
Possible Symptoms
- Climate Control not working (Not cooling)
Possible Causes
- Fuse(s) faulty
- Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280) faulty
- Compressor Regulating Valve (N280) faulty
- Heating/Climate Control Module (J301) faulty
Possible Solutions
- Check Fuse(s)
- Check Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280)
- Check/Replace Compressor Regulating Valve (N280)
- Check Measuring Value Blocks (MVB)
- Perform Output Test
- Check/Replace Heating/Climate Control Module (J301)
B10A915 - Control Circuit A/C Compressor: Open or Short to Plus
Possible Symptoms
- Climate Control not working (Not cooling)
Possible Causes
- Fuse(s) faulty
- Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280) faulty
- The wrong 2-wire electrical connector is plugged into the Regulating Valve (N280)
- Compressor Regulating Valve (N280) faulty
- Heating/Climate Control Module (J301) faulty
Possible Solutions
- Check Fuse(s)
- Check Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280)
- Verify the color of the wires matches the ones shown in the wiring diagram for N280 as per this thread
- Check/Replace Compressor Regulating Valve (N280)
- Check Measuring Value Blocks (MVB)
- Perform Output Test
- Check/Replace Heating/Climate Control Module (J301)
Special Notes
- The Refrigerant Compressor may need to be replaced if the Compressor Regulating Valve (N280) is not available separately.
- When found in the (4H) Audi A8 chassis 08-Auto HVAC control module, check the N280 AC compressor wiring to/from J519 per the factory level Wiring Diagram.