Readiness - APB Engine Code: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
| Line 2: | Line 2: | ||
'''<u>Prerequisites:</u>''' | '''<u>Prerequisites:</u>''' | ||
* Ignition ON and Engine | * Ignition ON and Engine OFF. | ||
'''[Select]'''<br> | |||
'''[01 - Engine]'''<br> | |||
'''[Fault Codes - 02]'''<br> | |||
'''[Clear Codes -05]'''<br> | |||
Channel 000<br> | Channel 000<br> | ||
'''[Read]'''<br> | '''[Read]'''<br> | ||
Revision as of 19:03, 5 October 2006
Manually Generating Readiness
Prerequisites:
- Ignition ON and Engine OFF.
[Select]
[01 - Engine]
[Fault Codes - 02]
[Clear Codes -05]
Channel 000
[Read]
[Save]
[Done, Go Back]
[Measuring Blocks - 08]
Block 010 (in 1st Row)
Block 011 (in 2nd Row)
[Go!]
Check fields 2, specification is ADP OK.
- Move the selector lever in position D and drive with partial load 20 m / 70 ft forward, then brake to standstill.
- Hold the brake for 10 seconds.
- Move the selector lever in position R and drive with partial load 20 m / 70 ft reverse, then brake to standstill.
- Hold the brake for 10 seconds.
The procedure needs to be repeated at least 5 times and can be repeated up to 10 times until the measuring values show ADP OK.
[Done, Go Back]
[Close Controller, Go Back - 06]
No categories.