Difference between revisions of "18436/P2004/008196"
From Ross-Tech Wiki
Line 27: | Line 27: | ||
*** Replace Intake Manifold Runner (V157) with updated part. | *** Replace Intake Manifold Runner (V157) with updated part. | ||
*** Additional information may be found by searching RVU 24M2 / O3 (Exp. date November 30, 2011) or calling the VW dealer and checking the VIN. | *** Additional information may be found by searching RVU 24M2 / O3 (Exp. date November 30, 2011) or calling the VW dealer and checking the VIN. | ||
− | + | * When found in 2012-2016 Audi with 3.0 TFSI, please see TPI 2050329 | |
+ | ** Vacuum operated water pump may draw excessive vacuum causing intake manifold flaps to malfunction. Updated vacuum hose for water pump. | ||
+ | *** https://static.nhtsa.gov/odi/tsbs/2018/MC-10133286-9999.pdf NHTSA | ||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Revision as of 14:10, 18 March 2021
18436/P2004/008196 - Intake Manifold Flap; Bank 1: Stuck Open
Possible Causes
- Vacuum leak
- Faulty Intake Manifold Runner Position Sensor1 (G336)
- Intake Manifold Runner binding or sticking
Possible Solutions
- Replaced failed vacuum line
- Check Intake Manifold Runner Position Sensor 1 (G336) and wiring, see repair manual
- Check Intake Manifold Flap
- Use Output Test
- Perform Basic Setting (Switch Ignition OFF between Output Test and Basic Setting)
Special Notes
- When found in Engine: 2.0l TFSI
- Perform Basic Setting.
- Check TPL 2016420 (RoW)
- Check Engine Control Module Software Version, if necessary perform Update.
- Replace Intake Manifold Runner (V157) with updated part.
- Check TSB 01-08-12 or 2018402 (NAR) North American Region vehicles only.
- Check Engine Control Module Software Version, if necessary perform Update.
- Replace Intake Manifold Runner (V157) with updated part.
- Additional information may be found by searching RVU 24M2 / O3 (Exp. date November 30, 2011) or calling the VW dealer and checking the VIN.
- When found in 2012-2016 Audi with 3.0 TFSI, please see TPI 2050329
- Vacuum operated water pump may draw excessive vacuum causing intake manifold flaps to malfunction. Updated vacuum hose for water pump.