Difference between revisions of "17082/P0698/001688"
From Ross-Tech Wiki
(Created page with "== 17082/P0698/001688 - Sensor Reference Voltage C: Too Low == ==== Possible Symptoms ==== * Malfunction Indicator Light (MIL) active ==== Possible Causes ==== * Failed b...") |
Sebastian1 (talk | contribs) m (Sebastian1 moved page 17082/P0698/001688 - Sensor Reference Voltage C: Too Low to 17082/P0698/001688) |
Latest revision as of 07:46, 28 April 2022
17082/P0698/001688 - Sensor Reference Voltage C: Too Low
Possible Symptoms
- Malfunction Indicator Light (MIL) active
Possible Causes
- Failed battery
- Poor electrical path
- Failed ECM
Possible Solutions
- Test battery, replace if needed
- Inspect battery cables, ground points, wiring harness, repair as needed
- Replace ECM