Difference between revisions of "16618/P0234/000564"
From Ross-Tech Wiki
RtWiKiSyS0p (talk | contribs) |
Gerrit Speek (talk | contribs) |
||
Line 10: | Line 10: | ||
* Hoses incorrect connected, disconnected, blocked or leaking | * Hoses incorrect connected, disconnected, blocked or leaking | ||
+ | * Malfunction N75 | ||
==== Possible Solutions ==== | ==== Possible Solutions ==== |
Revision as of 08:00, 3 June 2006
16618/P0234/000564 - Boost Pressure Regulation: Limit Exceeded (Overboost Condition)
Possible Symptoms
- Boost pressure too high
- Reduced power output
Possible Causes
- Hoses incorrect connected, disconnected, blocked or leaking
- Malfunction N75
Possible Solutions
- Check charge pressure control
- Check Solenoid Valve for Boost Pressure Control (N75)