Difference between revisions of "Readiness - APB Engine Code"
Line 22: | Line 22: | ||
'''[Go]'''<br> | '''[Go]'''<br> | ||
'''[Switch to basic settings]'''<br> | '''[Switch to basic settings]'''<br> | ||
− | Once you do this you will see the top right display say ADP RUN. Leave it in Basic Settings until the | + | Once you do this you will see the top right display say ADP RUN. Leave it in Basic Settings until the fourth field reads ADP OK.<br> |
'''[Switch to Meas. Blocks]'''<br> | '''[Switch to Meas. Blocks]'''<br> | ||
Line 31: | Line 31: | ||
'''[Go]'''<br> | '''[Go]'''<br> | ||
'''[Switch to basic settings]'''<br> | '''[Switch to basic settings]'''<br> | ||
− | Once you do this you will see the top right display say ADP RUN. Leave it in Basic Settings until the | + | Once you do this you will see the top right display say ADP RUN. Leave it in Basic Settings until the fourth field reads ADP OK.<br> |
'''[Switch to Meas. Blocks]'''<br> | '''[Switch to Meas. Blocks]'''<br> | ||
Line 48: | Line 48: | ||
'''[01 - Engine]'''<br> | '''[01 - Engine]'''<br> | ||
'''[Measuring Blocks - 08]'''<br> | '''[Measuring Blocks - 08]'''<br> | ||
− | Select group | + | Select group 071<br> |
'''[Go]'''<br> | '''[Go]'''<br> | ||
'''[Switch to basic settings]'''<br> | '''[Switch to basic settings]'''<br> | ||
− | + | Leave it in Basic Settings until the fourth field reads Syst.OK<br> | |
'''[Switch to Meas. Blocks]'''<br> | '''[Switch to Meas. Blocks]'''<br> | ||
+ | |||
+ | ''Evap purge test''<br> | ||
+ | |||
+ | Select group 071<br> | ||
+ | '''[Go]'''<br> | ||
+ | '''[Switch to basic settings]'''<br> | ||
+ | Leave it in Basic Settings until the fourth field reads Syst.OK<br> | ||
+ | '''[Switch to Meas. Blocks]'''<br> | ||
Revision as of 14:35, 5 October 2006
Manually Generating Readiness
- Ignition ON and Engine OFF
Reading and clearing fault codes
[Select]
[01 - Engine]
[Fault Codes - 02]
[Clear Codes -05]
[Done, Go Back]
Throttle Body Alignment
[Measuring Blocks - 08]
Select group 060
[Go]
[Switch to basic settings]
Once you do this you will see the top right display say ADP RUN. Leave it in Basic Settings until the fourth field reads ADP OK.
[Switch to Meas. Blocks]
Transmission kickdown (applies to Auto Trans vehicles only!)
Select group 063
[Go]
[Switch to basic settings]
Once you do this you will see the top right display say ADP RUN. Leave it in Basic Settings until the fourth field reads ADP OK.
[Switch to Meas. Blocks]
[Done, Go Back]
[Close Controller, Go Back]
- Ignition ON and Engine ON at idle
Fuel leakage test
[Select]
[01 - Engine]
[Measuring Blocks - 08]
Select group 071
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads Syst.OK
[Switch to Meas. Blocks]
Evap purge test
Select group 071
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads Syst.OK
[Switch to Meas. Blocks]
Channel 000
[Read]
[Save]
[Done, Go Back]
[Measuring Blocks - 08]
Block 010 (in 1st Row)
Block 011 (in 2nd Row)
[Go!]
Check fields 2, specification is ADP OK.
- Move the selector lever in position D and drive with partial load 20 m / 70 ft forward, then brake to standstill.
- Hold the brake for 10 seconds.
- Move the selector lever in position R and drive with partial load 20 m / 70 ft reverse, then brake to standstill.
- Hold the brake for 10 seconds.
The procedure needs to be repeated at least 5 times and can be repeated up to 10 times until the measuring values show ADP OK.
[Done, Go Back]
[Close Controller, Go Back - 06]