Difference between revisions of "00532"
From Ross-Tech Wiki
RtWiKiSyS0p (talk | contribs) m |
RtWiKiSyS0p (talk | contribs) m |
||
Line 19: | Line 19: | ||
* When found in multiple control modules at the same time, it's most likely a common source (e.g. ground spot, battery, generator). | * When found in multiple control modules at the same time, it's most likely a common source (e.g. ground spot, battery, generator). | ||
* Intermittent codes are often stored during low outside temperature when the battery capacity goes down and may be ignored. | * Intermittent codes are often stored during low outside temperature when the battery capacity goes down and may be ignored. | ||
+ | * Common with [[16946/P0562/001378|16946/P0562/001378 - System Voltage: Too Low]] stored in other control modules. | ||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Revision as of 18:00, 4 October 2007
00532 - Supply Voltage B+
00532 - Supply Voltage B+: Signal too Low
Possible Causes
- Wiring/Connectors from/to Control Module faulty
- Power Supply (Battery/Generator) faulty
Possible Solutions
- Check/Repair Wiring/Connectors from/to Control Module
- Check Power Supply (Battery/Generator)
Special Notes
- When found in an individual control module, it's most likely a local source (e.g. wiring/connectors).
- When found in multiple control modules at the same time, it's most likely a common source (e.g. ground spot, battery, generator).
- Intermittent codes are often stored during low outside temperature when the battery capacity goes down and may be ignored.
- Common with 16946/P0562/001378 - System Voltage: Too Low stored in other control modules.