Difference between revisions of "01317"

From Ross-Tech Wiki
(New page: __FORCETOC__ == 01317 - Instrument Cluster (J285) == === 01317 - Instrument Cluster (J285): No Communications === ==== Possible Causes ==== * CAN-Databus Wiring/Connectors from/to Instr...)
 
Line 29: Line 29:
  
 
* Instrument Cluster (J285) stored a Code which influences other Control Modules Functionality
 
* Instrument Cluster (J285) stored a Code which influences other Control Modules Functionality
 +
 +
 +
 +
=== 01317 - Instrument Cluster (J285): Implausible Signal ===
 +
 +
==== Special Notes ====
 +
 +
* When found in [[Audi A3/S3 (8P)]]: [[Audi A3 (8P) Climatronic|Heating/Air Conditioning]], check Instrument Cluster for Fault Codes.
  
 
[[Category:Fault Codes]]
 
[[Category:Fault Codes]]

Revision as of 16:08, 13 May 2008

01317 - Instrument Cluster (J285)

01317 - Instrument Cluster (J285): No Communications

Possible Causes

  • CAN-Databus Wiring/Connectors from/to Instrument Cluster (J285) faulty
  • Fault(s) stored in Instrument Cluster (J285)

Possible Solutions

  • Check CAN-Databus Wiring/Connectors from/to Instrument Cluster (J285)
  • Check Measuring Value Blocks (MVB)
    • Usually Measuring Value Blocks (MVB) 125+ show the current Communication Status


01317 - Instrument Cluster (J285): Check DTC Memory

Possible Causes

  • Fault(s) stored in Instrument Cluster (J285)

Possible Solutions

  • Check Instrument Cluster (J285) for Fault Codes

Special Notes

  • Instrument Cluster (J285) stored a Code which influences other Control Modules Functionality


01317 - Instrument Cluster (J285): Implausible Signal

Special Notes