Difference between revisions of "01317"
From Ross-Tech Wiki
RtWiKiSyS0p (talk | contribs) (New page: __FORCETOC__ == 01317 - Instrument Cluster (J285) == === 01317 - Instrument Cluster (J285): No Communications === ==== Possible Causes ==== * CAN-Databus Wiring/Connectors from/to Instr...) |
RtWiKiSyS0p (talk | contribs) |
||
Line 29: | Line 29: | ||
* Instrument Cluster (J285) stored a Code which influences other Control Modules Functionality | * Instrument Cluster (J285) stored a Code which influences other Control Modules Functionality | ||
+ | |||
+ | |||
+ | |||
+ | === 01317 - Instrument Cluster (J285): Implausible Signal === | ||
+ | |||
+ | ==== Special Notes ==== | ||
+ | |||
+ | * When found in [[Audi A3/S3 (8P)]]: [[Audi A3 (8P) Climatronic|Heating/Air Conditioning]], check Instrument Cluster for Fault Codes. | ||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Revision as of 16:08, 13 May 2008
01317 - Instrument Cluster (J285)
01317 - Instrument Cluster (J285): No Communications
Possible Causes
- CAN-Databus Wiring/Connectors from/to Instrument Cluster (J285) faulty
- Fault(s) stored in Instrument Cluster (J285)
Possible Solutions
- Check CAN-Databus Wiring/Connectors from/to Instrument Cluster (J285)
- Check Measuring Value Blocks (MVB)
- Usually Measuring Value Blocks (MVB) 125+ show the current Communication Status
01317 - Instrument Cluster (J285): Check DTC Memory
Possible Causes
- Fault(s) stored in Instrument Cluster (J285)
Possible Solutions
- Check Instrument Cluster (J285) for Fault Codes
Special Notes
- Instrument Cluster (J285) stored a Code which influences other Control Modules Functionality
01317 - Instrument Cluster (J285): Implausible Signal
Special Notes
- When found in Audi A3/S3 (8P): Heating/Air Conditioning, check Instrument Cluster for Fault Codes.