01317
From Ross-Tech Wiki
01317 - Instrument Cluster (J285)
01317 - Instrument Cluster (J285): No Communications
Possible Causes
- CAN-Databus Wiring/Connectors from/to Instrument Cluster (J285) faulty
- Fault(s) stored in Instrument Cluster (J285)
Possible Solutions
- Check CAN-Databus Wiring/Connectors from/to Instrument Cluster (J285)
- Check Measuring Value Blocks (MVB)
- Usually Measuring Value Blocks (MVB) 125+ show the current Communication Status
01317 - Instrument Cluster (J285): Check DTC Memory
Possible Causes
- Fault(s) stored in Instrument Cluster (J285)
Possible Solutions
- Check Instrument Cluster (J285) for Fault Codes
Special Notes
- Instrument Cluster (J285) stored a Code which influences other Control Modules Functionality
01317 - Instrument Cluster (J285): Implausible Signal
Special Notes
- When found in Audi A3/S3 (8P): Heating/Air Conditioning, check Instrument Cluster for Fault Codes.
- May be stored in Combination with 00003 - Control Module / 005 - No or Incorrect Basic Setting / Adaptation in the Instrument Cluster.