Difference between revisions of "02456"

From Ross-Tech Wiki
(New page: __FORCETOC__ == 02456 - Line Filling == === 02456 - Line Filling: No or Incorrect Basic Setting / Adaptation === ==== Possible Symptoms ==== * Fault Code can not be erased ==== Possibl...)
 
 
Line 19: Line 19:
 
==== Special Notes ====
 
==== Special Notes ====
  
* When found in [[VW Touran (1T)]]: [[VW Touran (1T) Auxiliary Heating|Auxiliary Heating]] ''(or similar)'', set Adaptation Channel 043 to a New Value of 1.
+
* When found in [[VW Touran (1T)]]: [[VW Touran (1T) Auxiliary Heating|Auxiliary Heating]] ''(or similar)'', perform Line Filling.
 +
** Set Adaptation Channel 030 to a New Value of 30.
 +
** Set Adaptation Channel 043 to a New Value of 0.
 +
** Perform Basic Setting in Measuring Value Block (MVB) 066.
  
 
[[Category:Fault Codes]]
 
[[Category:Fault Codes]]

Latest revision as of 09:43, 30 December 2008

02456 - Line Filling

02456 - Line Filling: No or Incorrect Basic Setting / Adaptation

Possible Symptoms

  • Fault Code can not be erased

Possible Causes

  • Line Filling not performed
  • New Auxiliary Heater installed

Possible Solutions

  • Perform Line Filling

Special Notes

  • When found in VW Touran (1T): Auxiliary Heating (or similar), perform Line Filling.
    • Set Adaptation Channel 030 to a New Value of 30.
    • Set Adaptation Channel 043 to a New Value of 0.
    • Perform Basic Setting in Measuring Value Block (MVB) 066.