Difference between revisions of "00819"
From Ross-Tech Wiki
RtWiKiSyS0p (talk | contribs) |
RtWiKiSyS0p (talk | contribs) |
||
Line 1: | Line 1: | ||
__FORCETOC__ | __FORCETOC__ | ||
== 00819 - High Pressure Sensor (G65) == | == 00819 - High Pressure Sensor (G65) == | ||
+ | |||
+ | === 00819 - High Pressure Sensor (G65): Open or Short to Ground === | ||
+ | |||
+ | ==== Possible Causes ==== | ||
+ | |||
+ | * Wiring/Connectors from/to High Pressure Sensor (G65) faulty | ||
+ | * High Pressure Sensor (G65) faulty | ||
+ | |||
+ | ==== Possible Solutions ==== | ||
+ | |||
+ | * Check Wiring/Connectors from/to High Pressure Sensor (G65) | ||
+ | * Check High Pressure Sensor (G65) | ||
+ | |||
=== 00819 - High Pressure Sensor (G65): Signal too Low === | === 00819 - High Pressure Sensor (G65): Signal too Low === |
Latest revision as of 17:30, 12 February 2009
00819 - High Pressure Sensor (G65)
00819 - High Pressure Sensor (G65): Open or Short to Ground
Possible Causes
- Wiring/Connectors from/to High Pressure Sensor (G65) faulty
- High Pressure Sensor (G65) faulty
Possible Solutions
- Check Wiring/Connectors from/to High Pressure Sensor (G65)
- Check High Pressure Sensor (G65)
00819 - High Pressure Sensor (G65): Signal too Low
Possible Symptoms
- Climate Control stuck in ECON Mode
Possible Causes
- Insufficient Refrigerant Pressure
- Wiring/Connectors from/to High Pressure Sensor (G65) faulty
- High Pressure Sensor (G65) faulty
Possible Solutions
- Check Refrigerant Pressure
- Check Measuring Value Blocks (MVB)
- Check Wiring/Connectors from/to High Pressure Sensor (G65)
- Check High Pressure Sensor (G65)