Difference between revisions of "16605/P0221/000545"
From Ross-Tech Wiki
RtWiKiSyS0p (talk | contribs) m |
|||
Line 15: | Line 15: | ||
** See Measuring Value Blocks (MVB) 060+ | ** See Measuring Value Blocks (MVB) 060+ | ||
* Check Wiring/Connector(s) from/to Throttle Body Control (J338) | * Check Wiring/Connector(s) from/to Throttle Body Control (J338) | ||
+ | |||
+ | ==== Special Notes ==== | ||
+ | |||
+ | * When found in the NAR [[2.0l TFSI (AXX/BGB/BPJ/BPY/BWA)|2.0l TFSI]]: (BPY, CCTA and CBFA) check TSB 01-09-04 or 2018652 for a wiring repair at the Throttle Body. | ||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Revision as of 17:21, 4 May 2010
16605/P0221/000545 - Angle Sensor for Throttle (G188): Implausible Signal
Possible Symptoms
- Malfunction Indicator Light (MIL) active
Possible Causes
- Wiring/Connector(s) from/to Throttle Body Control (J338) faulty
Possible Solutions
- Check Throttle Body Control (J338)
- See Measuring Value Blocks (MVB) 060+
- Check Wiring/Connector(s) from/to Throttle Body Control (J338)
Special Notes
- When found in the NAR 2.0l TFSI: (BPY, CCTA and CBFA) check TSB 01-09-04 or 2018652 for a wiring repair at the Throttle Body.