Difference between revisions of "01542"

From Ross-Tech Wiki
m
 
Line 6: Line 6:
 
==== Possible Symptoms ====
 
==== Possible Symptoms ====
  
* Malfunction Indicator Light (MIL) active
+
* Malfunction Indicator Light (MIL) ON
  
 
==== Possible Causes ====
 
==== Possible Causes ====
  
 +
* Wiring and/or Connector(s) from/to Yaw Rate Sensor (G202) faulty
 
* Yaw Rate Sensor (G202) faulty
 
* Yaw Rate Sensor (G202) faulty
 
* ESP-Sensor Unit (G419) faulty
 
* ESP-Sensor Unit (G419) faulty
Line 15: Line 16:
 
==== Possible Solutions ====
 
==== Possible Solutions ====
  
 +
* Check Wiring and/or Connector(s) from/to Yaw Rate Sensor (G202)
 
* Check Yaw Rate Sensor (G202)
 
* Check Yaw Rate Sensor (G202)
 +
** Check Measuring Value Block (MVB)
 +
* Check ESP-Sensor Unit (G419)
 +
 +
 +
=== 01542 - Yaw Rate Sensor (G202): Implausible Signal ===
 +
 +
==== Possible Symptoms ====
 +
 +
* Malfunction Indicator Light (MIL) ON
 +
 +
==== Possible Causes ====
 +
 +
* Ground Wiring and/or Connector(s) from/to Yaw Rate Sensor (G202) faulty
 +
* Installation Position of Yaw Rate Sensor (G202) incorrect
 +
* Yaw Rate Sensor (G202) faulty
 +
* ESP-Sensor Unit (G419) faulty
 +
 +
==== Possible Solutions ====
 +
 +
* Check Wiring and/or Connector(s) from/to Yaw Rate Sensor (G202)
 +
* Check Installation Position of Yaw Rate Sensor (G202)
 +
* Check Yaw Rate Sensor (G202)
 +
** Check Measuring Value Block (MVB)
 
* Check ESP-Sensor Unit (G419)
 
* Check ESP-Sensor Unit (G419)
  
Line 30: Line 55:
 
** See Vehicle specific [[Diagnostic Procedures]] for Details
 
** See Vehicle specific [[Diagnostic Procedures]] for Details
  
 +
__FORCETOC__
 
[[Category:Fault Codes]]
 
[[Category:Fault Codes]]

Latest revision as of 21:24, 13 November 2010

01542 - Yaw Rate Sensor (G202)

01542 - Yaw Rate Sensor (G202): Electrical Fault in Circuit

Possible Symptoms

  • Malfunction Indicator Light (MIL) ON

Possible Causes

  • Wiring and/or Connector(s) from/to Yaw Rate Sensor (G202) faulty
  • Yaw Rate Sensor (G202) faulty
  • ESP-Sensor Unit (G419) faulty

Possible Solutions

  • Check Wiring and/or Connector(s) from/to Yaw Rate Sensor (G202)
  • Check Yaw Rate Sensor (G202)
    • Check Measuring Value Block (MVB)
  • Check ESP-Sensor Unit (G419)


01542 - Yaw Rate Sensor (G202): Implausible Signal

Possible Symptoms

  • Malfunction Indicator Light (MIL) ON

Possible Causes

  • Ground Wiring and/or Connector(s) from/to Yaw Rate Sensor (G202) faulty
  • Installation Position of Yaw Rate Sensor (G202) incorrect
  • Yaw Rate Sensor (G202) faulty
  • ESP-Sensor Unit (G419) faulty

Possible Solutions

  • Check Wiring and/or Connector(s) from/to Yaw Rate Sensor (G202)
  • Check Installation Position of Yaw Rate Sensor (G202)
  • Check Yaw Rate Sensor (G202)
    • Check Measuring Value Block (MVB)
  • Check ESP-Sensor Unit (G419)


01542 - Yaw Rate Sensor (G202): No or Incorrect Basic Setting / Adaptation

Possible Causes

  • Yaw Rate Sensor (G202) Basic Setting lost/not performed

Possible Solutions