Difference between revisions of "17831/P1423/005155"

From Ross-Tech Wiki
 
Line 9: Line 9:
  
 
* Fuse for Secondary Air Injection Pump blown
 
* Fuse for Secondary Air Injection Pump blown
* Vacuum Hose(s) leaky
+
* Vacuum Hose(s) leaky or collapsed
* Piping between Secondary Air Injection Pump and Secondary Air Injection Valve leaking
+
* Piping between Secondary Air Injection Pump and Combi (Secondary Air Injection) Valve leaking
 +
* Secondary Air Injection Solenoid(s) faulty
 +
* Combi Valve(s) faulty
  
 
==== Possible Solutions ====
 
==== Possible Solutions ====
Line 16: Line 18:
 
* Check Fuse for Secondary Air Injection Pump
 
* Check Fuse for Secondary Air Injection Pump
 
* Check Vacuum Hose(s)
 
* Check Vacuum Hose(s)
* Check Piping between Secondary Air Injection Pump and Secondary Air Injection Valve
+
* Check Piping between Secondary Air Injection Pump and Combi (Secondary Air Injection) Valve
 +
* Check Secondary Air Injection Solenoid(s)
 +
* Check Combi Valve(s)
  
 
[[Category:Fault Codes]]
 
[[Category:Fault Codes]]

Revision as of 21:53, 3 March 2011

17831/P1423/005155 - Secondary Air Injection System; Bank 1: Insufficient Flow

Possible Symptoms

  • Malfunction Indicator Light (MIL) active

Possible Causes

  • Fuse for Secondary Air Injection Pump blown
  • Vacuum Hose(s) leaky or collapsed
  • Piping between Secondary Air Injection Pump and Combi (Secondary Air Injection) Valve leaking
  • Secondary Air Injection Solenoid(s) faulty
  • Combi Valve(s) faulty

Possible Solutions

  • Check Fuse for Secondary Air Injection Pump
  • Check Vacuum Hose(s)
  • Check Piping between Secondary Air Injection Pump and Combi (Secondary Air Injection) Valve
  • Check Secondary Air Injection Solenoid(s)
  • Check Combi Valve(s)