Difference between revisions of "02830"
From Ross-Tech Wiki
RtWiKiSyS0p (talk | contribs) |
|||
Line 21: | Line 21: | ||
==== Special Notes ==== | ==== Special Notes ==== | ||
− | * When found in [[VW Passat (3C) CAN-Gateway|VW Passat (3C): CAN-Gateway]], check Measuring Value Block (MVB) 002.3 | + | * When found in [[VW Passat (3C) CAN-Gateway|VW Passat (3C): CAN-Gateway]]: |
− | * | + | ** If the Car is equipped with Adaptive Cruise Control (ACC) or other Systems using the Extended CAN-Databus, check Measuring Value Block (MVB) 002.3. The Value should change between ''active'' and ''passive'' when the Ignition is being cycled. |
+ | ** If the [[VW Passat (3C) CAN-Gateway|CAN-Gateway]] has been replaced, check if Address '''4F - Central Electronics II''' is installed/listed in the Installation List . You may need to update the Gateway [http://www.ross-tech.com/vcds/tour/installation-list.html [Installation List]] to register this Control Module properly. | ||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Latest revision as of 09:47, 24 January 2013
02830 - Control Circuit for CAN Isolator for Driver Assistance Systems
02830 - Control Circuit for CAN Isolator for Driver Assistance Systems: Electrical Fault in Circuit
Possible Causes
- Supply Voltage insufficient
- Control Module Coding incorrect
- Incorrect Control Module installed
Possible Solutions
- Check Control Module Power Supply
- Check Control Module Coding (see Vehicle specific Diagnostic Procedures).
- Check CAN-Databus Powertrain Cut-Off Relay (J788)
- Check Measuring Value Blocks (MVB)
- Perform Output Test and check for an audible noise while the Relay is being actuated.
- Check if Control Module (Part Number) fits the Car's Equipment
Special Notes
- When found in VW Passat (3C): CAN-Gateway:
- If the Car is equipped with Adaptive Cruise Control (ACC) or other Systems using the Extended CAN-Databus, check Measuring Value Block (MVB) 002.3. The Value should change between active and passive when the Ignition is being cycled.
- If the CAN-Gateway has been replaced, check if Address 4F - Central Electronics II is installed/listed in the Installation List . You may need to update the Gateway [Installation List] to register this Control Module properly.