User:Peter: Difference between revisions

Peter (talk | contribs)
No edit summary
Dana (talk | contribs)
No edit summary
Line 2: Line 2:




'''Prerequisites:'''<br>
'''<u>Prerequisites:</u>'''<br>
- Battery Voltage = 12.0 - 14.0'''<br>
* Battery Voltage = 12.0 - 14.0 V'''<br>
- No fault codes other than [01087-Basic Setting Not Performed]'''<br>
* No fault codes other than [[01087 | 01087 - Basic Setting Not Performed]]'''<br>
- Vehicle is lifted off the ground, on a suitable vehicle lift'''<br>
* Vehicle is lifted off the ground, on a suitable vehicle lift'''<br>




Line 12: Line 12:
'''[Meas. Blocks - 08]'''<br>
'''[Meas. Blocks - 08]'''<br>
Note: The values stored in the Measuring Value Blocks below are the Minimum and Maximum sensor values.'''<br>
Note: The values stored in the Measuring Value Blocks below are the Minimum and Maximum sensor values.'''<br>
Group-054 Field-1 = G78 - Min value'''<br>
* Group-054 Field-1 = G78 - Min value'''<br>
Group-054 Field-2 = G78 - Max value'''<br>
* Group-054 Field-2 = G78 - Max value'''<br>
<br>
<br>
Group-055 Field-1 = G289 - Min value'''<br>
* Group-055 Field-1 = G289 - Min value'''<br>
Group-055 Field-2 = G289 - Max value'''<br>
* Group-055 Field-2 = G289 - Max value'''<br>
<br>
<br>
'''Look at:'''<br>
'''Look at:'''<br>
'''Group-003 - Field-1,2,3 -  Actual Sensor values'<br>
'''Group-003 - Field-1,2,3 -  Actual Sensor values'''<br>
- If the values are with in the range of the Min - Max stored values from MVBs 054 and 055 then'''<br>
If the values are with in the range of the Min - Max stored values from MVBs 054 and 055 then Basic settings can be performed, if not inspect suspension or sensors.'''<br>
Basic settings can be performed, if not inspect suspension or sensors.'''<br>
<br>
<br>
'''[Security Access - 16]'''<br>
'''[Security Access - 16]'''<br>
Line 27: Line 26:
'''[Do it!]'''<br>
'''[Do it!]'''<br>
'''[Basic Settings - 04]'''<br>
'''[Basic Settings - 04]'''<br>
'''Group 001'''<br>
Group 001<br>
'''[Go!]'''<br>
'''[Go!]'''<br>
<br>
<br>
The New values should be displayed.'''<br>
The New values should be displayed.'''<br>
- To check the learned values, check Measuring Value Group-008.'''<br>
To check the learned values, check Measuring Value Group-008.'''<br>
[Meas. Blocks - 08]'''<br>
'''[Meas. Blocks - 08]'''<br>
Enter [008] - Go!'''<br>
Group 008<br>
'''[Go!]'''<br>
The values displayed should be the learned values as displayed in the Basic Settings window.'''<br>
The values displayed should be the learned values as displayed in the Basic Settings window.'''<br>

Revision as of 15:18, 30 May 2013

Electronic Damping Control J250 - Basic Settings

Prerequisites:


[Select]
[14 - Susp. Elect]
[Meas. Blocks - 08]
Note: The values stored in the Measuring Value Blocks below are the Minimum and Maximum sensor values.

  • Group-054 Field-1 = G78 - Min value
  • Group-054 Field-2 = G78 - Max value


  • Group-055 Field-1 = G289 - Min value
  • Group-055 Field-2 = G289 - Max value


Look at:
Group-003 - Field-1,2,3 - Actual Sensor values

  • If the values are with in the range of the Min - Max stored values from MVBs 054 and 055 then Basic settings can be performed, if not inspect suspension or sensors.


[Security Access - 16]
Enter 31564, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 001
[Go!]

The New values should be displayed.

  • To check the learned values, check Measuring Value Group-008.

[Meas. Blocks - 08]
Group 008
[Go!]
The values displayed should be the learned values as displayed in the Basic Settings window.