Difference between revisions of "00898"

From Ross-Tech Wiki
(Created page with '== 00898 - Control Circuit A/C Compressor == === 00898 - Control Circuit A/C Compressor: Open or Short to Plus === ==== Possible Symptoms ==== * Climate Control not working =…')
 
Line 53: Line 53:
  
 
* The Compressor Regulating Valve (N280) may not be available separately, in this case the entire Refrigerant Compressor needs to be replaced.
 
* The Compressor Regulating Valve (N280) may not be available separately, in this case the entire Refrigerant Compressor needs to be replaced.
 +
 +
 +
=== 00898 - Control Circuit A/C Compressor: No or incorrect Basic Settings ===
 +
 +
*When found in the [[VW Jetta (16/AJ)]] or [[VW Beetle (5C/AT)]] Manual Heating/Air Conditioning controller, please see this page for the Basic Settings procedure.
 +
** [[VW Jetta (AJ/16) Manual Heating/Air Conditioning]]
 +
 +
  
 
__FORCETOC__
 
__FORCETOC__
 
[[Category:Fault Codes]]
 
[[Category:Fault Codes]]

Revision as of 13:28, 2 January 2015

00898 - Control Circuit A/C Compressor

00898 - Control Circuit A/C Compressor: Open or Short to Plus

Possible Symptoms

  • Climate Control not working

Possible Causes

  • Fuse(s) faulty
  • Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280) faulty
  • Compressor Regulating Valve (N280) faulty
  • Heating/Climate Control Module (J301) faulty

Possible Solutions

  • Check Fuse(s)
  • Check Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280)
  • Check/Replace Compressor Regulating Valve (N280)
    • Check Measuring Value Blocks (MVB)
    • Perform Output Test
  • Check/Replace Heating/Climate Control Module (J301)

Special Notes

  • The Compressor Regulating Valve (N280) may not be available separately, in this case the entire Refrigerant Compressor needs to be replaced.


00898 - Control Circuit A/C Compressor: Short to Ground

Possible Symptoms

  • Climate Control not working

Possible Causes

  • Fuse(s) faulty
  • Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280) faulty
  • Compressor Regulating Valve (N280) faulty
  • Heating/Climate Control Module (J301) faulty

Possible Solutions

  • Check Fuse(s)
  • Check Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280)
  • Check/Replace Compressor Regulating Valve (N280)
    • Check Measuring Value Blocks (MVB)
    • Perform Output Test
  • Check/Replace Heating/Climate Control Module (J301)

Special Notes

  • The Compressor Regulating Valve (N280) may not be available separately, in this case the entire Refrigerant Compressor needs to be replaced.


00898 - Control Circuit A/C Compressor: No or incorrect Basic Settings