Revision as of 19:47, 18 July 2015
01273 - Fresh Air Blower (V2)
Possible Causes
- Fresh Air Blower (V2) defective
- Control Module for Fresh Air Blower (J126) defective
- Short of open circuit in wiring to Fresh Air Blower (V2)
- Climatronic Control Module (J255) malfunctioning
Possible Solutions
- Check Fresh Air Blower (V2)
- Perform Output Test (Check Air Vents while Blower is active)
- Check Meas. Blocks while Blower is active
- Check Control Module for Fresh Air Blower (J126)
- Perform Output Test (Check Air Vents while Blower is active)
- Check wiring and connectors
- Start with the Air Blower Fuse. Is it good? Is it in the CORRECT location in the fuse box?
Special Notes
- When found in Audi A4/A5/Q5 (8K/8T/8R) models:
- North American Market (NAR) vehicles, see TPI 2033596/3 (or newer)
- RoW vehicles, see TPI 2022372/2 (or newer)