Difference between revisions of "Audi TT (8J)Automatic Roof"
(Created page with "__FORCETOC__ == Coding == Not Applicable == Adaptation == When performing repairs/replacement of the Flap Motors it will be necessary to perform the Adaption of the Flap Mo...") |
|||
Line 12: | Line 12: | ||
The faults associated with the bulletins include: [[02000]], [[03246]], and [[03247]]. | The faults associated with the bulletins include: [[02000]], [[03246]], and [[03247]]. | ||
− | + | After diagnosis and repairs per TPI 2015779 (Convertible top adjustment options) perform the following Output Test: | |
+ | |||
+ | '''[Select]'''<br> | ||
+ | '''[26 - Auto Roof]'''<br> | ||
+ | '''[Output Tests - 03]'''<br> | ||
+ | '''[Select]''' Selective Output Tests<br> | ||
+ | '''[Choose]'''''Convertible Top Flap Initialisation'' <br> | ||
+ | '''[Start]'''<br> | ||
+ | '''Operate''' the Convertible Top throughout a complete Open/Close sequence BEFORE exiting the Output Test function.<br> | ||
+ | '''[Done, Go Back]'''<br> | ||
+ | '''[Close Controller, Go Back - 06]'''<br><br> | ||
+ | |||
+ | ---- | ||
+ | |||
+ | Additional Output Tests on both right and left Flap Motors can be completed if needed:<br> | ||
'''[Select]'''<br> | '''[Select]'''<br> |
Revision as of 10:03, 10 August 2015
Coding
Not Applicable
Adaptation
When performing repairs/replacement of the Flap Motors it will be necessary to perform the Adaption of the Flap Motors.
Ref: TSB 61-09-02 or 2018777 for NAR (North American Region) vehicles.
The faults associated with the bulletins include: 02000, 03246, and 03247.
After diagnosis and repairs per TPI 2015779 (Convertible top adjustment options) perform the following Output Test:
[Select]
[26 - Auto Roof]
[Output Tests - 03]
[Select] Selective Output Tests
[Choose]Convertible Top Flap Initialisation
[Start]
Operate the Convertible Top throughout a complete Open/Close sequence BEFORE exiting the Output Test function.
[Done, Go Back]
[Close Controller, Go Back - 06]
Additional Output Tests on both right and left Flap Motors can be completed if needed:
[Select]
[26 - Auto Roof]
[Output Tests - 03]
[Select] Selective Output Tests
[Choose] - Motor for Convertible Top Flap Left (V383)
[Start]
Wait until the Flap has open and closed,
[Choose] - Motor for Convertible Top Flap Right (V381)
[Start]
Wait until the Flap has open and closed, then
Operate the Convertible Top 3 times, Open/close = 1 time, do this 2 more times.
[Done, Go Back]
[Close Controller, Go Back - 06]
Check Measuring Value Blocks Group 008 to verify correct values of the Flap Motors.
Important Note:
- You must operate the Convertible Top before exiting the Output Tests Window.
- If you do not operate the Top, the adaption of the flaps will not be learnt!