Difference between revisions of "VW Golf (1K) Instrument Cluster"
(→Note) |
(→Coding) |
||
Line 22: | Line 22: | ||
** 6 = 22420 | ** 6 = 22420 | ||
** 7 = 22532 | ** 7 = 22532 | ||
− | + | This thread contains some interesting discussion on the meaning of the Distance Impulse Multiplier: | |
+ | http://forums.tdiclub.com/showpost.php?p=3393030&postcount=8 | ||
== Security Access == | == Security Access == |
Latest revision as of 14:09, 9 December 2015
Coding
- 00??x0x: Options
- +01 = Brake Pad Warning
- +02 = Seatbelt Warning
- +04 = Washer Fluid Warning
- +16 = Sedan (only VW Jetta)
- 00xx?0x: Country
- 1 = Europe (EU)
- 2 = USA (US)
- 3 = Canada (CDN)
- 4 = Great Britain (GB)
- 5 = Japan (JP)
- 6 = Saudi Arabia (SA)
- 7 = Australia (AUS)
- 00xxx0?: Distance Impulse Number
- 1 = 22188
- 2 = 22076
- 3 = 21960
- 4 = 21848
- 5 = 22304
- 6 = 22420
- 7 = 22532
This thread contains some interesting discussion on the meaning of the Distance Impulse Multiplier: http://forums.tdiclub.com/showpost.php?p=3393030&postcount=8
Security Access
- 13861 = Adaptation Enabling
Adaptation
Channel 002: Service Reminder
- 0 = Service NOT Due
- 1 = Service Due
To reset the service reminder save 0 as new value.
Channe 003: Consumption Correction
- Standard Value: 100 %
- Display Range: 85...115 %
- Increments: 1 %
New Adaptation Value = Old Adaptation Value * Calculated Consumption / Old Display Value
Channel 004: Language
- 1 = German
- 2 = English
- 3 = French
- 4 = Italian
- 5 = Spanish
- 6 = Portuguese
- 7 = No Text
- 8 = Czech
Channel 009: Mileage/Odometer
- Increments: 1 = 10 km or 1 = 10 mi
The distance can only be changed once before the current value is not over 100 km/62 mi. After changing the value can be corrected within the next 5 km/3 mi of driving.
Channel 022: Production Mode
Channel 030: Fuel Gauge Adaptation
- Standard: 100
- Range: 120...136
- Increments: 1 Ohm
Channel 035: Speed Threshold
This value represents the speed threshold of the dynamic oil pressure system. The threshold can be raised in increments of 250 RPM.
Channel 038: Oil Minimum Detection
With this function the oil-minimum-warning at low oil level can be deactivated or activated.
Channel 039: Oil Level Sensor Adaptation
Determines if the TOG Sensor is installed or not.
Channel 040: Mileage since Service
- Increments: 1 = 100 km
Channel 041: Time since Service
- Increments: 1 = 1 day(s)
Channel 042: Minimum Distance to Service
- Increments: 1 = 1000 km
Channel 043: Maximum Distance to Service
- Increments: 1 = 1000 km
Channel 044: Maximum Time to Service
- Increments: 1 = 1 day(s)
- 365 = fixed Service Intervals (w/o Longlife)
- 730 = flexible Service Intervals (with Longlife)
Channel 045: Oil Quality
- 1 = fixed Service Intervals (w/o Longlife)
- 2 = flexible Service Intervals (with Longlife)
Channel 046: Total Consumption
Channel 047: Soot Entry
Channel 048: Thermal Load
Channel 049: Minimum Time to Service
- Increments: 1 = 1 day(s)
- 365 = fixed Service Intervals (w/o Longlife)
- 730 = flexible Service Intervals (with Longlife)
Note