Difference between revisions of "01418"
From Ross-Tech Wiki
RtWiKiSyS0p (talk | contribs) (Created page with '== 01418 - Switch Valve 1 for Electronic Stability Program (N225) == ==== Possible Symptoms ==== * Malfunction Indicator Light (MIL) ON ==== Possible Causes ==== * Fuse(s) fa…') |
|||
Line 17: | Line 17: | ||
* Check Wiring and/or Connector(s) from/to Brake Electronics (J104) | * Check Wiring and/or Connector(s) from/to Brake Electronics (J104) | ||
** Check Wiring and/or Connector(s) from/to Valve Power Supply | ** Check Wiring and/or Connector(s) from/to Valve Power Supply | ||
+ | ** Perform Output Test | ||
* Check/Replace Brake Electronics (J104) | * Check/Replace Brake Electronics (J104) | ||
** Perform Output Test | ** Perform Output Test |
Latest revision as of 17:46, 7 March 2016
01418 - Switch Valve 1 for Electronic Stability Program (N225)
Possible Symptoms
- Malfunction Indicator Light (MIL) ON
Possible Causes
- Fuse(s) faulty
- Wiring and/or Connector(s) from/to Brake Electronics (J104) faulty
- Wiring and/or Connector(s) from/to Valve Power Supply faulty
- Brake Electronics (J104) faulty
Possible Solutions
- Check Fuse(s)
- Check Wiring and/or Connector(s) from/to Brake Electronics (J104)
- Check Wiring and/or Connector(s) from/to Valve Power Supply
- Perform Output Test
- Check/Replace Brake Electronics (J104)
- Perform Output Test