Difference between revisions of "VW Touareg (7L) Trunk Electronics"
From Ross-Tech Wiki
Line 16: | Line 16: | ||
== Basic Setting == | == Basic Setting == | ||
=== Rear Lid relearn === | === Rear Lid relearn === | ||
+ | '''<u>Prerequisites:</u>'''<br> | ||
+ | * Rear Lid closed. | ||
'''[Select]'''<br> | '''[Select]'''<br> | ||
Line 25: | Line 27: | ||
Group 001<br> | Group 001<br> | ||
'''[Go!]'''<br> | '''[Go!]'''<br> | ||
+ | The rear lid Basic Settings will now begin and the rear lid will now open. If the lid does not open use the '''[On/Off/Next]''' button.<br> | ||
'''[Done, Go Back]'''<br> | '''[Done, Go Back]'''<br> | ||
− | |||
− | |||
*When the rear lid has stopped, close the rear lid. | *When the rear lid has stopped, close the rear lid. | ||
*Check for fault codes, clear if needed. | *Check for fault codes, clear if needed. |
Revision as of 10:00, 8 March 2016
This page applies to Address-6D: Trunk Elect.in the VW Touareg (7L6) with Component: J605 HECKKLAPPE. This can be identified by evaluating the data in the Auto-Scan:
Address 6D: Trunk Elect. Labels: None Part No SW: 7L6 959 107 B HW: 7L6 959 107 B Component: J605 HECKKLAPPE 1310
Security Access
- Security Access codes will appear when connected to the control module with VCDS.
Coding
- This control module is Short coded.
- When replacing this module save the original coding and transfer it to the new module.
Basic Setting
Rear Lid relearn
Prerequisites:
- Rear Lid closed.
[Select]
[6D-Trunk Elect.]
[Security Access - 16]
Enter 59107
[Do it!]
[Basic Settings - 04]
Group 001
[Go!]
The rear lid Basic Settings will now begin and the rear lid will now open. If the lid does not open use the [On/Off/Next] button.
[Done, Go Back]
- When the rear lid has stopped, close the rear lid.
- Check for fault codes, clear if needed.
[Close Controller, Go Back - 06]
- Check for proper operation
- Re-check for faults
Internal use references: ST?ID=59047 -and- ST?ID=37245