Difference between revisions of "01049"

From Ross-Tech Wiki
 
Line 7: Line 7:
  
 
* Fuse(s) faulty
 
* Fuse(s) faulty
* Wiring and/or Connector(s) from/to Alternator Relay (J53) faulty
+
* Wiring and/or Connector(s) from/to Starter Relay (J53) faulty
* Alternator Relay (J53) faulty
+
* Starter Relay (J53) faulty
  
 
==== Possible Solutions ====
 
==== Possible Solutions ====
  
 
* Check Fuse(s)
 
* Check Fuse(s)
* Check Wiring and/or Connector(s) from/to Alternator Relay (J53)
+
* Check Wiring and/or Connector(s) from/to Starter Relay (J53)
* Check/Replace Alternator Relay (J53)
+
* Check/Replace Starter Relay (J53)
  
 
==== Special Notes ====
 
==== Special Notes ====

Latest revision as of 16:50, 5 February 2020

01049 - Supply Voltage Term 50

01049 - Supply Voltage Term 50: Short to Plus

Possible Causes

  • Fuse(s) faulty
  • Wiring and/or Connector(s) from/to Starter Relay (J53) faulty
  • Starter Relay (J53) faulty

Possible Solutions

  • Check Fuse(s)
  • Check Wiring and/or Connector(s) from/to Starter Relay (J53)
  • Check/Replace Starter Relay (J53)

Special Notes

  • When found in Audi A6 (4F): Access/Start Authorization, check Measuring Value Blocks.


01049 - Supply Voltage Term 50: Electrical Fault in Circuit

Possible Solutions

  • Check Ignition Switch (D) Terminal 50