01049 - Supply Voltage Term 50
-
1.1.1
01049 - Supply Voltage Term 50: Short to Plus
- 1.1.1.2 Possible Causes
- 1.1.2.2 Possible Solutions
- 1.1.3.2 Special Notes
-
1.1.1
01049 - Supply Voltage Term 50: Short to Plus
RtWiKiSyS0p (talk | contribs) No edit summary |
No edit summary |
||
| Line 7: | Line 7: | ||
* Fuse(s) faulty | * Fuse(s) faulty | ||
* Wiring and/or Connector(s) from/to | * Wiring and/or Connector(s) from/to Starter Relay (J53) faulty | ||
* | * Starter Relay (J53) faulty | ||
==== Possible Solutions ==== | ==== Possible Solutions ==== | ||
* Check Fuse(s) | * Check Fuse(s) | ||
* Check Wiring and/or Connector(s) from/to | * Check Wiring and/or Connector(s) from/to Starter Relay (J53) | ||
* Check/Replace | * Check/Replace Starter Relay (J53) | ||
==== Special Notes ==== | ==== Special Notes ==== | ||
Latest revision as of 21:50, 5 February 2020
01049 - Supply Voltage Term 50
01049 - Supply Voltage Term 50: Short to Plus
Possible Causes
- Fuse(s) faulty
- Wiring and/or Connector(s) from/to Starter Relay (J53) faulty
- Starter Relay (J53) faulty
Possible Solutions
- Check Fuse(s)
- Check Wiring and/or Connector(s) from/to Starter Relay (J53)
- Check/Replace Starter Relay (J53)
Special Notes
- When found in Audi A6 (4F): Access/Start Authorization, check Measuring Value Blocks.
01049 - Supply Voltage Term 50: Electrical Fault in Circuit
Possible Solutions
- Check Ignition Switch (D) Terminal 50