Difference between revisions of "VW Golf (5K) Climatic"

From Ross-Tech Wiki
 
Line 19: Line 19:
 
'''[08 - Heating/Air Conditioning]'''<br>
 
'''[08 - Heating/Air Conditioning]'''<br>
 
'''[Basic Settings - 04]'''<br>
 
'''[Basic Settings - 04]'''<br>
Select "Adapt flap end stops" from the drop-down list<br>
+
Select IDE01546-ENG167462 "Adapt flap end stops" from the drop-down list<br>
 
'''[Go!]'''<br>
 
'''[Go!]'''<br>
 
The basic setting takes approximately 20 seconds.<br>
 
The basic setting takes approximately 20 seconds.<br>
Line 46: Line 46:
 
[[VW Golf (5K) Climatic#Adapt flap end stops | Adapt flap end stops]] as described above.<br>
 
[[VW Golf (5K) Climatic#Adapt flap end stops | Adapt flap end stops]] as described above.<br>
 
'''[Basic Settings - 04]'''<br>
 
'''[Basic Settings - 04]'''<br>
Select "Compressor Run In; Automatic Start" from the drop-down list.<br>
+
Select IDE02259-ENG167462 "Compressor run in: automatic start" from the drop-down list.<br>
 
'''[Go!]'''<br>
 
'''[Go!]'''<br>
 
* It will show completed, but wait 120 sec (2 Min) and observe the flashing A/C button light on the HVAC panel.
 
* It will show completed, but wait 120 sec (2 Min) and observe the flashing A/C button light on the HVAC panel.

Latest revision as of 16:58, 30 July 2020


Coding

  • Coding information is found using the Long Coding Helper while connected to the vehicle with VCDS.
  • When replacing a module it is recommended to save the original coding and transfer it to the new module.



Basic Setting

Note: The basic setting needs to be performed, when the Climatic control module (J301) or flap motor(s) have been replaced.

Adapt flap end stops

Necessary when flap motors are replaced -or- when a self check needs to be performed for self diagnosis of faulty motors.

[Select]
[08 - Heating/Air Conditioning]
[Basic Settings - 04]
Select IDE01546-ENG167462 "Adapt flap end stops" from the drop-down list
[Go!]
The basic setting takes approximately 20 seconds.
Finished Correctly should be displayed
[Stop]
[Done, Go Back]
[Close Controller, Go Back - 06]



AC Compressor First Run-In

Necessary when the Climatic control module (J301) is replaced.

Prerequisites to start the basic setting A/C compressor first run:

  • Engine at idle
  • Transmission in Park or Neutral
  • Do not cycle the ignition
  • Basic setting was performed for the flaps
  • Inside blower motor is switched on
  • Air vents fully open
  • Load management not active


"AC Compressor First Run-In" Steps:
Start engine and allow it to Idle.
Adapt flap end stops as described above.
[Basic Settings - 04]
Select IDE02259-ENG167462 "Compressor run in: automatic start" from the drop-down list.
[Go!]

  • It will show completed, but wait 120 sec (2 Min) and observe the flashing A/C button light on the HVAC panel.
  • After the Basic Settings has completed, the A/C light will quit flashing and the fault code will clear.

[Stop]
Note: If Basic Settings reports Error the module may need to see an Adaptation change before this can be completed. Go to Adaptation and change "Driving time for compressor run in" from 120 -to- 120 and save it followed by repeating the entire procedure.