Difference between revisions of "B10A9"

From Ross-Tech Wiki
 
Line 36: Line 36:
 
* Fuse(s) faulty
 
* Fuse(s) faulty
 
* Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280) faulty
 
* Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280) faulty
 +
** The wrong 2-wire electrical connector is plugged into the Regulating Valve (N280)
 
* Compressor Regulating Valve (N280) faulty
 
* Compressor Regulating Valve (N280) faulty
 
* Heating/Climate Control Module (J301) faulty
 
* Heating/Climate Control Module (J301) faulty
Line 43: Line 44:
 
* Check Fuse(s)
 
* Check Fuse(s)
 
* Check Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280)
 
* Check Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280)
 +
** Verify the color of the wires matches the ones shown in the wiring diagram for N280 as per [https://forums.ross-tech.com/index.php?threads/633/ this thread]
 
* Check/Replace Compressor Regulating Valve (N280)
 
* Check/Replace Compressor Regulating Valve (N280)
 
** Check Measuring Value Blocks (MVB)
 
** Check Measuring Value Blocks (MVB)

Latest revision as of 16:54, 5 May 2021

B10A9 - Control Circuit for A/C Compressor

B10A911 - Control Circuit A/C Compressor: Short to Ground

Possible Symptoms

  • Climate Control not working (Not cooling)

Possible Causes

  • Fuse(s) faulty
  • Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280) faulty
  • Compressor Regulating Valve (N280) faulty
  • Heating/Climate Control Module (J301) faulty

Possible Solutions

  • Check Fuse(s)
  • Check Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280)
  • Check/Replace Compressor Regulating Valve (N280)
    • Check Measuring Value Blocks (MVB)
    • Perform Output Test
  • Check/Replace Heating/Climate Control Module (J301)


B10A915 - Control Circuit A/C Compressor: Open or Short to Plus

Possible Symptoms

  • Climate Control not working (Not cooling)

Possible Causes

  • Fuse(s) faulty
  • Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280) faulty
    • The wrong 2-wire electrical connector is plugged into the Regulating Valve (N280)
  • Compressor Regulating Valve (N280) faulty
  • Heating/Climate Control Module (J301) faulty

Possible Solutions

  • Check Fuse(s)
  • Check Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280)
    • Verify the color of the wires matches the ones shown in the wiring diagram for N280 as per this thread
  • Check/Replace Compressor Regulating Valve (N280)
    • Check Measuring Value Blocks (MVB)
    • Perform Output Test
  • Check/Replace Heating/Climate Control Module (J301)



Special Notes

  • The Refrigerant Compressor may need to be replaced if the Compressor Regulating Valve (N280) is not available separately.
  • When found in the (4H) Audi A8 chassis 08-Auto HVAC control module, check the N280 AC compressor wiring to/from J519 per the factory level Wiring Diagram.
    • If coolant or water migration damaged the wiring harnesses you may find this DTC in conjunction with 01232, B10A9 or B10C6.
    • The following pages contains a photos from a (4H) 4.2L A8L with corrosion damaged 4H A8L 14b pin connector: