Difference between revisions of "U1122"
From Ross-Tech Wiki
(Created page with "__FORCETOC__ == U1122 - Databus == === U1122 - Databus: Implausible Message === ==== Special Notes ==== * When this exact DTC is found in Address 3C: Lane Change (J769) on...") |
|||
Line 14: | Line 14: | ||
* Check for updated TPIs. At present TPI 2061819 / TSB 96-21-69 has two revisions: | * Check for updated TPIs. At present TPI 2061819 / TSB 96-21-69 has two revisions: | ||
− | + | ** https://static.nhtsa.gov/odi/tsbs/2020/MC-10185258-0001.pdf NHTSA | |
− | + | ** https://static.nhtsa.gov/odi/tsbs/2021/MC-10197967-0001.pdf NHTSA | |
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Latest revision as of 13:26, 19 September 2024
U1122 - Databus
U1122 - Databus: Implausible Message
Special Notes
- When this exact DTC is found in Address 3C: Lane Change (J769) on the F3 chassis Q3 the cause is most likely buggy factory software:
1188157 - Databus U1122 00 [009] - Implausible Message [databus unreasonable message - Perso_Status] Confirmed - Tested Since Memory Clear
- Check for updated TPIs. At present TPI 2061819 / TSB 96-21-69 has two revisions: