Audi TT (8J)Automatic Roof: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
- 1. Coding
- 2. Adaptation
No edit summary |
|||
Line 6: | Line 6: | ||
== Adaptation == | == Adaptation == | ||
After repairs/replacement of the Flap Motors it will be necessary to perform the | |||
Adaption of the Flap Motors. | Adaption of the Flap Motors. Useful references include:<br> | ||
* NAR (North American Region) TSB 61-09-02 or 2018777 | |||
The faults associated with the bulletins include: [[02000]], [[03246]], and [[03247]]. | * NAR (North American Region) TPI 2015779: | ||
** https://static.nhtsa.gov/odi/tsbs/2013/MC-10121348-9999.pdf NHTSA | |||
* The faults associated with the bulletins include: [[02000]], [[03246]], and [[03247]]. <br> | |||
After diagnosis and repairs | |||
After diagnosis and repairs perform the following Output Test: | |||
'''[Select]'''<br> | '''[Select]'''<br> |
Latest revision as of 16:25, 18 October 2024
Coding
Not Applicable
Adaptation
After repairs/replacement of the Flap Motors it will be necessary to perform the
Adaption of the Flap Motors. Useful references include:
- NAR (North American Region) TSB 61-09-02 or 2018777
- NAR (North American Region) TPI 2015779:
- The faults associated with the bulletins include: 02000, 03246, and 03247.
After diagnosis and repairs perform the following Output Test:
[Select]
[26 - Auto Roof]
[Output Tests - 03]
[Select] Selective Output Tests
[Choose]Convertible Top Flap Initialisation
[Start]
Operate the Convertible Top throughout a complete Open/Close sequence BEFORE exiting the Output Test function.
[Done, Go Back]
[Close Controller, Go Back - 06]
This thread contains 8J chassis [26-Auto Roof] data:
No categories.