Readiness - APB Engine Code

From Ross-Tech Wiki

Manually Generating Readiness

  • Ignition ON and Engine OFF.

Reading and clearing fault codes

[Select]
[01 - Engine]
[Fault Codes - 02]
[Clear Codes -05]
[Done, Go Back]


Throttle Body Alignment

[Measuring Blocks - 08]
Select group 060
[Go]
[Switch to basic settings]
Once you do this you will see the top right display say ADP RUN. The TB adaptation is being done as soon as you switch to basic settings. You will see the values change and hear the TB cycle for the first few seconds then it will stop. Leave it in Basic Settings for about 30 seconds.
[Switch to Meas. Blocks]


Channel 000
[Read]
[Save]
[Done, Go Back]
[Measuring Blocks - 08]
Block 010 (in 1st Row)
Block 011 (in 2nd Row)
[Go!]
Check fields 2, specification is ADP OK.

  • Move the selector lever in position D and drive with partial load 20 m / 70 ft forward, then brake to standstill.
  • Hold the brake for 10 seconds.
  • Move the selector lever in position R and drive with partial load 20 m / 70 ft reverse, then brake to standstill.
  • Hold the brake for 10 seconds.

The procedure needs to be repeated at least 5 times and can be repeated up to 10 times until the measuring values show ADP OK.
[Done, Go Back]
[Close Controller, Go Back - 06]