16395/P0011/000017
From Ross-Tech Wiki
Revision as of 12:21, 24 March 2008 by RtWiKiSyS0p (talk | contribs)
16395/P0011/000017 - Bank 1: Camshaft A (Intake): Retard Setpoint not Reached (Over-Advanced)
Possible Symptoms
- Power Loss
Possible Causes
- Camshaft Adjustment Valve 1 (N205) faulty
- Fuel Pump Relay (J17) faulty
Possible Solutions
- Check Camshaft Adjustment Valve 1 (N205)
- Check Fuel Pump Relay (J17)
Special Notes
- When found in Engine: 4.0l W8
- Check TPL 2010059(RoW)
- Check/Replace Oil Sieve in Timing Case (Camshaft Adjuster)
- Check TPL 2010059(RoW)