1.
00668 - Supply Voltage Terminal 30
-
1.1.1
00668 - Supply Voltage Terminal 30: Signal Outside Specifications
- 1.1.1.2 Possible Causes
- 1.1.2.2 Possible Solutions
- 1.1.3.2 Special Notes
-
1.1.1
00668 - Supply Voltage Terminal 30: Signal Outside Specifications
00668 - Supply Voltage Terminal 30
00668 - Supply Voltage Terminal 30: Signal Outside Specifications
Possible Causes
- Fuse(s) faulty
- Wiring/Connectors from/to Control Module faulty
- Power Supply (Battery/Generator) faulty
Possible Solutions
- Check Fuse(s)
- Check/Repair Wiring/Connectors from/to Control Module
- Check Power Supply (Battery/Generator)
Special Notes
- When found in an individual control module, it's most likely a local source (e.g. wiring/connectors).
- When found in multiple control modules at the same time, it's most likely a common source (e.g. ground spot, battery, generator).
- Intermittent codes are often stored during low outside temperature when the battery capacity goes down and may be ignored.