Audi TT (8J)Automatic Roof
Coding
Not Applicable
Adaptation
When performing repairs/replacement of the Flap Motors it will be necessary to perform the Adaption of the Flap Motors.
Ref: TSB 61-09-02 or 2018777 for NAR (North American Region) vehicles.
The faults associated with the bulletins include: 02000, 03246, and 03247.
After diagnosis and repairs per TPI 2015779 (Convertible top adjustment options) perform the following Output Test:
[Select]
[26 - Auto Roof]
[Output Tests - 03]
[Select] Selective Output Tests
[Choose]Convertible Top Flap Initialisation
[Start]
Operate the Convertible Top throughout a complete Open/Close sequence BEFORE exiting the Output Test function.
[Done, Go Back]
[Close Controller, Go Back - 06]
Additional Output Tests on both right and left Flap Motors can be completed if needed:
[Select]
[26 - Auto Roof]
[Output Tests - 03]
[Select] Selective Output Tests
[Choose] - Motor for Convertible Top Flap Left (V383)
[Start]
Wait until the Flap has open and closed,
[Choose] - Motor for Convertible Top Flap Right (V381)
[Start]
Wait until the Flap has open and closed, then
Operate the Convertible Top 3 times, Open/close = 1 time, do this 2 more times.
[Done, Go Back]
[Close Controller, Go Back - 06]
Check Measuring Value Blocks Group 008 to verify correct values of the Flap Motors.
Important Note:
- You must operate the Convertible Top before exiting the Output Tests Window.
- If you do not operate the Top, the adaption of the flaps will not be learnt!