User:Peter

From Ross-Tech Wiki
Revision as of 10:18, 30 May 2013 by Dana (talk | contribs)

Electronic Damping Control J250 - Basic Settings

Prerequisites:


[Select]
[14 - Susp. Elect]
[Meas. Blocks - 08]
Note: The values stored in the Measuring Value Blocks below are the Minimum and Maximum sensor values.

  • Group-054 Field-1 = G78 - Min value
  • Group-054 Field-2 = G78 - Max value


  • Group-055 Field-1 = G289 - Min value
  • Group-055 Field-2 = G289 - Max value


Look at:
Group-003 - Field-1,2,3 - Actual Sensor values

  • If the values are with in the range of the Min - Max stored values from MVBs 054 and 055 then Basic settings can be performed, if not inspect suspension or sensors.


[Security Access - 16]
Enter 31564, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 001
[Go!]

The New values should be displayed.

  • To check the learned values, check Measuring Value Group-008.

[Meas. Blocks - 08]
Group 008
[Go!]
The values displayed should be the learned values as displayed in the Basic Settings window.