03389

From Ross-Tech Wiki
Revision as of 09:35, 28 May 2019 by Peter (talk | contribs) (→‎Possible Solutions)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

03389 - Data Set Implausible

Possible Causes

  • Control module was replaced

Possible Solutions

  • An online connection with the manufacture is required for Parameterization via the SVM (Software Version Management).

Special Notes

  • Parameterization refers to data written into the control unit by the SVM function (Software Version Management) to customize the software functionality for the specific vehicle or country of operation.
  • Often referred to as the “calibration data”, it is necessary Parameterization is performed anytime there is missing or invalid data-set fault codes and/or it is suggested by SVM test plan to ensure the proper functionality of the control unit.
  • Not all control units are parameterized by SVM.
  • Parameterization MUST BE PERFORMED to ensure the control unit will function properly in the vehicle!