P3053 - Starter Control; Returned Message: 50 Short to Ground

Special Notes

  • When found in MQB Golf based models such as the 2018 - 2019 (CDVC) 3.6L Vr6 VW Atlas verify the fuse to T91a/88 terminal of the ECM (623) labeled "SIG" in the wiring diagram is OK. A blown or missing fused power supply to that terminal of the ECM will result in this DTC. This was fuse SB22 on the 2019 Atlas we received feedback from.