02432
From Ross-Tech Wiki
Revision as of 09:46, 19 February 2008 by RtWiKiSyS0p (talk | contribs) (New page: __FORCETOC__ == 02432 - Supply Voltage for Left Parking Brake Motor (V282) == === 02432 - Supply Voltage for Left Parking Brake Motor (V282): Electrical Fault in Circuit === === 02432 - S...)
02432 - Supply Voltage for Left Parking Brake Motor (V282)
02432 - Supply Voltage for Left Parking Brake Motor (V282): Electrical Fault in Circuit
02432 - Supply Voltage for Left Parking Brake Motor (V282): Open Circuit
Possible Symptoms
- Parking Brake Warning Light active/flashing
Possible Causes
- Wiring/Connectors from/to Left Parking Brake Motor (V282) faulty
- Left Parking Brake Motor (V282) Power Supply faulty
Possible Solutions
- Check Wiring/Connectors from/to Left Parking Brake Motor (V282)
- Check Left Parking Brake Motor (V282) Power Supply
- Perform Terminal 30 Reset
- Remove Fuse(s) for a short Time.
Special Notes
- Make sure to cycle the Parking Brake a couple of times between checking for Fault Codes, this will ensure that the Control Module tests the related Components again.