02432 - Supply Voltage for Left Parking Brake Motor (V282)

02432 - Supply Voltage for Left Parking Brake Motor (V282): Electrical Fault in Circuit

02432 - Supply Voltage for Left Parking Brake Motor (V282): Open Circuit

Possible Symptoms

  • Parking Brake Warning Light active/flashing

Possible Causes

  • Wiring/Connectors from/to Left Parking Brake Motor (V282) faulty
  • Left Parking Brake Motor (V282) Power Supply faulty

Possible Solutions

  • Check Wiring/Connectors from/to Left Parking Brake Motor (V282)
  • Check Left Parking Brake Motor (V282) Power Supply
  • Perform Terminal 30 Reset
    • Remove Fuse(s) for a short Time.

Special Notes

  • Make sure to cycle the Parking Brake a couple of times between checking for Fault Codes, this will ensure that the Control Module tests the related Components again.