Readiness - APB Engine Code

From Ross-Tech Wiki
Revision as of 14:46, 5 October 2006 by Andy (talk | contribs)

Manually Generating Readiness

  • Ignition ON and Engine OFF


Reading and clearing fault codes

[Select]
[01 - Engine]
[Fault Codes - 02]
[Clear Codes -05]
[Done, Go Back]


Throttle Body Alignment

[Measuring Blocks - 08]
Select group 060
[Go]
[Switch to basic settings]
Once you do this you will see the top right display say ADP RUN. Leave it in Basic Settings until the fourth field reads ADP OK.
[Switch to Meas. Blocks]


Transmission kickdown (applies to Auto Trans vehicles only!)

Select group 063
[Go]
[Switch to basic settings]
Once you do this you will see the top right display say ADP RUN. Leave it in Basic Settings until the fourth field reads ADP OK.
[Switch to Meas. Blocks]


[Done, Go Back]
[Close Controller, Go Back]


  • Ignition ON and Engine ON at idle


Fuel leakage test

[Select]
[01 - Engine]
[Measuring Blocks - 08]
Select group 071
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads Syst.OK
[Switch to Meas. Blocks]


Evap purge test

Select group 070
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads EVAP OK
[Switch to Meas. Blocks]


A/F control test

Select group 107
[Go]
[Switch to basic settings]
Leave it in Basic Settings until the fourth field reads Syst.OK
[Switch to Meas. Blocks]


  • Ignition ON and Engine ON between 1800 and 2200 rpm


O2 sensor heater test

Select group 041
[Go]
[Switch to basic settings]
Leave it in Basic Settings until there are kOhm readings in the first and third fields
[Switch to Meas. Blocks]
Select group 042
[Go]
[Switch to basic settings]
Leave it in Basic Settings until there are kOhm readings in the first and third fields
[Switch to Meas. Blocks]


  • Ignition ON and Engine ON at idle


O2 sensor heater test

Select group 041
[Go]
[Switch to basic settings]
Leave it in Basic Settings until there are kOhm readings in the first and third fields
[Switch to Meas. Blocks]
Select group 042
[Go]
[Switch to basic settings]
Leave it in Basic Settings until there are kOhm readings in the first and third fields
[Switch to Meas. Blocks]